Elevating Devices Safety Regulation, B.C. Reg. 101/2004
Section 38
Rotating platforms
Cite as Elevating Devices Safety Regulation, B.C. Reg. 101/2004, s. 38 · last amended March 31, 2022 · read from BC Laws on November 17, 2026
The text
A rotating platform must comply with the following specifications:
(a) a minimum running clearance of 61 cm must be maintained at all shear points;
(b) the maximum running clearance between the rim of the rotating platform and the floor sill is 6 mm;
(c) the maximum rim speed must not exceed 30 cm/sec.;
(d) all motor control circuitry must be equipped with phase reversal protection;
(e) all rotating platforms must be reversible from the control unit or must incorporate in their design a reversing mechanism conveniently accessible to the attendant;
(f) a fused lock-off type disconnect switch must be located at the control unit and a remote lockable disconnect switch must be located convenient to each motor drive unit;
(g) a red emergency stop button must be conveniently located in each quarter section of the platform travel;
(h) the maximum platform travel, after an emergency stop has been initiated, is 5 cm;
(i) all control units must be key operated and the key must return to neutral position when released.
Read the Elevating Devices Safety Regulation on BC Laws ↗
Made under Safety Standards Act, SBC 2003, c. 39.