Electrical Safety Regulation, B.C. Reg. 100/2004
Section 17
When a homeowner may perform electrical work under a permit
Cite as Electrical Safety Regulation, B.C. Reg. 100/2004, s. 17 · last amended March 4, 2025 · read from BC Laws on November 17, 2026
The text
(1) Subject to this section, a homeowner may perform electrical work in their fully detached dwelling under an installation permit.
(2) An installation permit may be issued to a homeowner only if
(a) electricity is not fed or supplied from the fully detached dwelling to a separately owned or occupied property, and
(b) the electrical work involves only installations in which the current and voltage do not exceed current of 200 amps and voltage of 150 volts to ground, single phase power.
(3) An installation permit issued under subsection (2) does not authorize the issue of a permit to install the connection from a manufactured home or recreational vehicle to the power supply of a manufactured home park or recreational vehicle park.
(4) A homeowner who performs electrical work under an installation permit must request that the work be inspected by a safety officer
(a) if the work or a phase of the work is completed, promptly on that completion, or
(b) if no other inspection has been made within 180 days from the start of the permit, immediately before the expiry of the 180 day period.
(5) If an inspection is required after a request under subsection (4), the inspection must be made after completion of the electrical work and before
(a) the concealment of any portion of the rough wiring, and
(b) the connection of power to the electrical supply system.
(6) A homeowner may perform the electrical work in the homeowner's fully detached dwelling under an installation permit issued to a licensed electrical contractor for that work if
(a) the contractor who holds the permit supervises the work, and
(b) the homeowner only performs work referred to in subsection (2).
Read the Electrical Safety Regulation on BC Laws ↗
Made under Safety Standards Act, SBC 2003, c. 39.