Canada Oil and Gas Installations Regulations, SOR/96-118

Section 9

Cite as Canada Oil and Gas Installations Regulations, SOR/96-118, s. 9 · current to July 24, 2025 · regulation last amended October 6, 2020

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) Subject to subsection (2), there shall not be direct access or any opening in an installation between (a) a non-hazardous area and a hazardous area; or (b) a Class I, Division 2, hazardous area and a Class I, Division 1, hazardous area. (2) Subject to subsections (3) to (5), an enclosed area that has direct access to, and that is classified as less hazardous than, a Class I, Division 1, hazardous area or a Class I, Division 2, hazardous area shall be considered to have the same classification as the area to which it has direct access. (3) An enclosed area that has direct access to a Class I, Division 1, area shall be considered to be a Class I, Division 2, hazardous area if (a) the access is fitted with a self-closing gastight door that opens into the enclosed area; and (b) when the door is open, the air flows from the enclosed area into the Class I, Division 1, hazardous area. (4) An enclosed area shall not be considered to be a hazardous area because of its direct access to a Class I, Division 2, hazardous area if (a) the access is fitted with a self-closing gastight door that opens into the enclosed area; and (b) when the door is open, the air flows from the enclosed area into the Class I, Division 2, hazardous area. (5) An enclosed area shall not be considered to be a hazardous area because of its direct access to a Class I, Division 1, hazardous area if (a) the access is fitted with self-closing gastight doors forming an air-lock; and (b) the enclosed area is maintained at a pressure that is higher than the pressure maintained in the Class I, Division 1, hazardous area. (6) Piping systems on an installation shall be designed to preclude direct communications between hazardous areas of different classifications and between hazardous and non-hazardous areas.
Read the Canada Oil and Gas Installations Regulations on the Justice Laws Website ↗

Made under Canada Oil and Gas Operations Act, R.S.C. 1985, c. O-7.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.