Canada Oil and Gas Installations Regulations, SOR/96-118

Section 8

Cite as Canada Oil and Gas Installations Regulations, SOR/96-118, s. 8 · current to July 24, 2025 · regulation last amended October 6, 2020

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) In this section flame-type equipment means any electric or fired heating equipment that uses an open flame, electric arc or element, and includes a space heater, a torch, a heated process vessel, a boiler, an electric arc or an open flame welder, or an open element electric heater or appliance; (équipement de type à flamme) process vessel means a heater, dehydrator, separator, treater or vessel used in the processing or treatment of produced gas or oil. (récipient de fabrication) (2) No person shall create or cause to be created any unprotected flame or source of ignition within 50 m of a well, an oil storage tank or other source of ignitable vapour. (3) No oil storage tank shall be placed or remain within 50 m of an onshore well. (4) No flame-type equipment shall be placed or operated within 25 m of a well, an oil storage tank or other source of ignitable vapour, except (a) where the well is (i) a water supply well, or (ii) a water injection well equipped with a suitable packer and with the surface casing annulus vented outside any building; or (b) where emergency work requires the use of flame-type equipment and the wellhead valves and blow-out preventer, if any, are closed. (5) No flame-type equipment shall be placed or operated within 25 m of a process vessel, unless the flame type equipment is fitted with an adequate flame arrester. (6) No flame-type equipment shall be located in the same building as a process vessel or other source of ignitable vapour, unless (a) the air intakes and flues of all burners are located outside the building; (b) relief valves, safety heads and other sources of ignitable vapours are vented outside the building and discharged above roof level; and (c) the building is adequately cross-ventilated. (7) All process vessels and equipment from which ignitable vapour may issue shall be vented to the atmosphere, and all vent lines from every storage tank that is vented to flare pits or flare stacks shall be provided with flame arresters or other equivalent safety devices. (8) An exhaust pipe from an internal combustion engine located within 25 m of a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed so that (a) any emergence of flame along its length or at its end is prevented; and (b) the end is at least 6 m from the vertical centre line of the well projected upward and shall be directed away from the well. (9) All equipment at or near a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed in accordance with Part I of the Canadian Electrical Code Part I and the Oil and Gas Occupational Health and Safety Regulations.
Read the Canada Oil and Gas Installations Regulations on the Justice Laws Website ↗

Made under Canada Oil and Gas Operations Act, R.S.C. 1985, c. O-7.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.