Canada Oil and Gas Installations Regulations, SOR/96-118

Section 59

Cite as Canada Oil and Gas Installations Regulations, SOR/96-118, s. 59 · current to July 24, 2025 · regulation last amended October 6, 2020

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The boundaries of watertight compartments in a floating platform shall contain no more openings than necessary for the operation of the platform and, where penetration of those boundaries is necessary for access, ventilation, piping and cables or any other similar purpose, arrangements shall be made to maintain the strength and watertight integrity of the boundaries. (2) Every watertight boundary and associated closing appliance on a floating platform shall be of sufficient strength and tightness of closure to withstand without failure the pressure and other loads likely to occur in service. (3) All watertight doors and hatches on a floating platform shall be operable locally from both sides of the associated bulkhead or deck. (4) Side scuttles and windows on a floating platform shall be of the non-opening type, fitted with internal hinged deadlight covers. (5) All pipes and ducts on a floating platform shall, where possible, be routed clear of those compartments that are vulnerable to penetration damage or, where such routing is not possible, positive means of closure of those pipes and ducts shall be provided for each watertight boundary. (6) Every valve required at a watertight boundary on a floating platform shall be remotely operable from the ballast control station or by a mechanical means from another readily accessible position that is above the waterline in the final condition of equilibrium that could result when the platform is in a damaged condition. (7) Every inlet or discharge port on a floating platform that is submerged at maximum operating draught shall be fitted with a valve that is remotely controlled from the ballast control station, and each such valve shall close automatically when the source of power fails, unless safety considerations require that it remain open. (8) Every discharge port on a floating platform that penetrates a boundary to a compartment intended to be watertight shall be fitted with an automatic non-return valve and with a second such valve or with a device whereby the port may be closed from a position outside and above the compartment. (9) Every door or hatch on a floating platform used to ensure the watertight integrity of internal access openings during the operation of the platform shall, while the platform is afloat, be equipped with an indicator at the ballast control station to indicate whether the door or hatch is open or closed. (10) Every door or hatch on a floating platform that is normally closed while the platform is afloat shall be equipped (a) with an alarm system that is triggered in a manned control station when the door or hatch is open; and (b) with a notice affixed to that door or hatch cover to the effect that the door or hatch cover is not to be left open while the platform is afloat. (11) All external openings on a floating platform, except manholes that are fitted with close-bolted watertight covers and that are kept permanently closed while the platform is afloat, shall, in the intact condition or in a damaged condition, be completely above any waterline associated with the platform being heeled because of wind forces. (12) Every external opening on a floating platform that becomes wholly or partially submerged when the platform is at the maximum angle of heel that could occur while the platform meets the area ratio requirement for intact and damage stability set out in the Code referred to in subsection 57(9) or that may become intermittently submerged because of wave action when the platform is in a damaged condition shall (a) be designed and constructed to withstand any sea condition without penetration; (b) in the case of an opening that may become intermittently submerged when the platform is in a damaged condition, (i) close automatically when submerged, (ii) be readily and quickly closable at any time, or (iii) be assumed to be open in the damage stability calculations made pursuant to section 57; (c) in the case of an external opening that cannot be quickly closed, (i) be assumed to be open in damage stability calculations made pursuant to section 57, or (ii) be permanently closed when the platform is afloat; (d) in the case of a door or hatch that may be used during operation of the platform, be equipped with closing appliances that are operable locally from both sides of the bulkhead or deck; (e) in the case of a door or hatch that may become intermittently submerged when the platform is in a damaged condition, (i) be equipped with an indication system to show in the ballast control station the status of the closing appliances, (ii) be self-closing on being submerged, or readily and quickly closable, and (iii) bear a notice to the effect that the door or hatch is not to be left open during operation of the platform; (f) in the case of a ventilator or ventilation intake or outlet that may be used during operation of the platform, (i) be equipped with a self-activating anti-flooding device, or (ii) if it is an intake or outlet not subject to intermittent submergence when the platform is in a damaged condition, be fitted with a manually operated means of closure that is readily accessible; (g) in the case of a closing appliance that is not to be opened during operation of the platform, bear a notice to that effect; (h) in the case of air pipes to a ballast tank, be equipped with an anti-flooding device; and (i) in the case of a chain locker opening on a column-stabilized platform, except where the chain locker is kept full of water or is designed to be free-flooding, be fitted with a device that will prevent significant ingress of water in the event of submergence and with a suitable means for pumping out, both of which are remotely operable from a ballast control station. (13) All of the closing appliances required by subsection (12) shall be able to withstand without failure any wave impact load to which they may be subjected. (14) Every compartment on a floating platform required to remain watertight to comply with the intact and damage stability criteria described in section 57 shall incorporate a device suitably positioned to detect flooding and, where flooding occurs, trigger an alarm in a ballast control station.
Read the Canada Oil and Gas Installations Regulations on the Justice Laws Website ↗

Made under Canada Oil and Gas Operations Act, R.S.C. 1985, c. O-7.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.