Canada Oil and Gas Geophysical Operations Regulations, SOR/96-117
Section 19
Cite as Canada Oil and Gas Geophysical Operations Regulations, SOR/96-117, s. 19 · current to July 24, 2025 · regulation last amended March 22, 2006
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Every operator who is conducting an onshore geophysical operation shall, when a shot hole is being drilled for a charge, ensure that
(a) no drilling is done within 5 m of a shot hole that contains a charge, whether or not the charge has been detonated; and
(b) the shot hole is of sufficient size to allow the insertion of a charge into position in the shot hole without the use of undue force.
(2) Every operator who is conducting an onshore geophysical operation shall, when a shot hole is being drilled in an area that is prone to deposits of shallow gas, ensure that
(a) the drilling rig is positioned, with respect to the wind, so that gas encountered during drilling will not accumulate in the vicinity of the rig;
(b) the drilling rig is free from heat sources that might ignite any gas that has accumulated in the vicinity of the rig; and
(c) the engine is equipped with air intake shut-off valves that can be activated by the driller.
(3) Every operator who is conducting an onshore geophysical operation shall, when gas is encountered during drilling, and where it can be done safely, allowing sufficient time to permit evacuation, ensure that the air intake shut-off valves on the engine are placed in the off position.
Read the Canada Oil and Gas Geophysical Operations Regulations on the Justice Laws Website ↗
Made under Canada Oil and Gas Operations Act, R.S.C. 1985, c. O-7.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.