Reduction in the Release of Volatile Organic Compounds (Storage and Loading of Volatile Petroleum Liquids) Regulations, SOR/2025-88

Section 110

Tanks

Cite as Reduction in the Release of Volatile Organic Compounds (Storage and Loading of Volatile Petroleum Liquids) Regulations, SOR/2025-88, s. 110 · current to July 24, 2025 · regulation last amended July 5, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The operator of a facility must maintain, in respect of each tank at the facility designated under section 12, a record that contains the following information and any supporting documents: (a) the identifier of the tank; (b) the year of the tank’s installation and the design specifications of the tank, including (i) the internal volume of the tank, calculated in accordance with section 15, (ii) the height and diameter of the tank, and (iii) the type and identifier of any emissions control equipment installed on the tank; (c) the description of each liquid stored in the tank and the dates on which the tank contained the liquid, including, in the case of a volatile petroleum liquid, its vapour pressure, benzene concentration and, if it is an oil-water mixture, VOC concentration; (d) if the interior of the tank is cleaned for the purposes of paragraph 7(2)(a), the value of the LEL% inside the tank, the identifier of the instrument that was used to determine that value and an indication of whether mechanical ventilation was used during that determination; (e) the category to which the tank was designated to belong under section 12, the date on which it was first designated, any changes made to the designation, the date on which those changes were made and the reasons for those changes; (f) if the tank is used as an intermittent service tank under subsection 10(1), information to establish that it has been in service for 300 hours or less per calendar year and, if applicable, the statistical or engineering analysis referred to in subsection 10(3); (g) if the tank is used as a surge tank under subsection 11(1), a description of the abnormal operating conditions and the liquids transferred into the tank and the dates on which the liquids were transferred to or removed from the tank; (h) a maintenance plan for the tank that includes (i) the dates of any scheduled maintenance and an indication of whether the tank will be removed from service during the maintenance, and (ii) the latest allowable dates of the next inspections under subsections 91(1), 93(1), 94(1) and 95(1) and sections 96 and 97, as applicable, considering any applicable reduction of an inspection interval under section 99; (i) the dates and the duration of any periods during which the tank’s internal floating roof or external floating roof was resting on a support structure or suspended under subsection 61(2) or (3) or 70(2), as applicable; (j) information on the inspections of the tank or its internal floating roof or external floating roof required under subsection 91(1), 92(7), 93(1), 94(1) or 95(1) or sections 96 or 97, as applicable, including (i) the date of each inspection performed, (ii) if an inspection was omitted, the reason why and an indication of whether the inspection was omitted under subsection 91(2), (iii) if an inspection was not performed within the applicable time limit, the reason why and an indication of whether the inspection was delayed under subsection 94(2), (iv) the provision of these Regulations under which each inspection was performed, (v) the results of each inspection, including a description and the location of any detected defects, (vi) for each inspection of an internal floating roof, (A) the measured LEL% in the space above the internal floating roof and the baseline LEL% calculated under section 92, (B) the identifier of the instrument that was used to measure the LEL%, (C) an indication of whether the measurement was part of a second inspection under subsection 92(7), (D) the estimated wind speed at the time that the measurement was taken, and (E) the volume of liquid in the tank at the time that the measurement was taken and eight hours before that time, and (vii) the name of the person who performed each inspection, the name of their employer, and in the case of an inspection performed under subsection 93(1) or section 96, proof demonstrating that the person holds the certificate required under section 98; (k) testing and inspection records referred to in paragraph 93(2)(a) that are used to establish when the 20-year period referred to in subsection 93(1) begins, if applicable; (l) information on any detected defect referred to in subsection 100(5) or 101(1) of the tank or its internal floating roof or external floating roof, including, as applicable, (i) the date on which the defect was detected, (ii) a description of the defect, (iii) the date on which the defect was repaired, (iv) a description of the repair and the results of any necessary tests or inspections that are performed to confirm whether the repair is successful, (v) if the defect was not repaired within the applicable time limit set out in section 100, the reason why, (vi) if the tank’s internal floating roof or external floating roof has a defect referred to in subsection 101(1) (A) the date on which the operator ceased filling the tank with volatile petroleum liquid, (B) the date on which the operator emptied the tank of all volatile petroleum liquid in accordance with paragraph 101(2)(a), or the date on which the operator equipped the tank with a temporary vapour control system in accordance with paragraph 101(2)(b) and the date on which use of the temporary system began, as applicable, and (C) the factors taken into account in the choice of measures referred to in subsection 101(2), and (vii) if a rim seal of the tank has a defect, information on any determinations made for the purposes of subsections 100(3) and (4), including (A) the date on which the person referred to in paragraph 100(3)(b) determined that the tank is free of any other defects, the name of that person, the name of their employer and proof demonstrating that the person holds the certificate required under that paragraph, (B) the date on which the operator determined under subsection 100(4) that the defect of the rim seal could not be repaired while the tank is in service, if applicable, and (C) an indication of whether the repair was attempted while the tank is in service; (m) a copy of any VOC emissions minimization plan developed under subsection 103(1) in respect of the tank, including an indication of any deviations to the measures included in the plan and the date on which the plan was completed; (n) if the operator implements an extended repair plan in respect of the tank under subsection 106(1) for one of the reasons referred to in paragraph 106(1)(b) or (c), the date on which the operator ceased filling the tank with any volatile petroleum liquids; and (o) an indication of whether the tank has been designated under subsection 125(1) as a deferred application tank and, if applicable, the expected date on which the designation will no longer apply to the tank. (2) The operator must maintain, in respect of each tank at the facility not designated under section 12 that has an internal volume greater than or equal to 150 m3, a record that contains the following information and any supporting documents: (a) the identifier of the tank; (b) the internal volume of the tank; (c) the height and diameter of the tank; and (d) a description of the liquid stored in the tank, if any.
Read the Reduction in the Release of Volatile Organic Compounds (Storage and Loading of Volatile Petroleum Liquids) Regulations on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.