Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector), SOR/2020-231

Section 16

Record keeping

Cite as Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector), SOR/2020-231, s. 16 · current to July 24, 2025 · regulation last amended January 1, 2023

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The operator must, for each calendar year, keep a record of the following information: (a) in respect of an open-ended pipe that is not located in an emergency shutdown system, the identification number of the open-ended pipe and a description of the design considerations taken into account, and the control technologies and operating practices used, to ensure that the ends of the pipe are plugged in accordance with section 12; (b) in respect of a sampling system that is connected to a pipe, the identification number of the sampling system and a description of the design considerations taken into account, and the control technologies and operating practices used, to ensure that the sampling system is designed and used in accordance with section 13; (c) in respect of a pressure relief device, the identification number of the pressure relief device and a description of the design considerations taken into account, and the control technologies and operating practices used, to ensure that the device is designed and used in accordance with section 14; (d) in respect of a pressure release referred to in subsection 14(2), if the pressure relief device did not minimize, to the extent possible, the release of VOCs into the environment during a period of more than one hour, (i) the identification number of the pressure relief device, (ii) the day on which the pressure release ended, and (iii) the day on which the pressure relief device was returned to a condition that minimizes, to the extent possible, the release of VOCs into the environment; (e) in respect of a centrifugal compressor, other than one referred to in subsection 15(6), (i) the identification number of the compressor, (ii) an indication that the mechanical seal system of the compressor meets the requirements referred to in paragraph 15(2)(a), (b) or (c), as applicable, (iii) an indication that the barrier fluid referred to in subsection 15(3) contains less than 10% VOCs by weight, (iv) an indication that the compressor is equipped with the sensor referred to in subsection 15(4), and (v) an indication of whether or not the sensor is equipped with an audible alarm for the purpose of indicating a failure of the barrier fluid system or a mechanism that shuts down the compressor in the event of such a failure; (f) in respect of each daily sensor check carried out under subsection 15(5), (i) the identification number of the compressor that has the sensor that was checked, (ii) the day on which the sensor check was carried out, and (iii) the results of the sensor check; and (g) in respect of a centrifugal compressor referred to in subsection 15(6), the identification number of the compressor and a description of its closed-vent system. (2) The operator must retain the record, as well as any supporting documents, at the facility for at least five years.
Read the Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector) on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.