Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector), SOR/2020-231

Section 12

Pipes

Cite as Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector), SOR/2020-231, s. 12 · current to July 24, 2025 · regulation last amended January 1, 2023

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The ends of a pipe that is not located in an emergency shutdown system must be plugged at all times using a method that minimizes, to the extent possible, the release of VOCs into the environment, including the use of a cap, a blind flange or a plug or the use of two valves that are operated so that the valve on the process fluid end is closed before the other valve is closed. (2) Subsection (1) does not apply in respect of a pipe that comes into contact with a fluid that would autocatalytically polymerize or would create any other safety hazard, if the pipe were plugged in accordance with that subsection. (3) Subsection (1) does not apply during an operation that requires the ends of a pipe to be open.
Read the Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector) on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.