Vessel Fire Safety Regulations, SOR/2017-14
Section 343
Cite as Vessel Fire Safety Regulations, SOR/2017-14, s. 343 · current to July 24, 2025 · regulation last amended November 23, 2022
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) A placard containing the following warning must be posted near the means of control for a fixed gas fire-extinguishing system:WARNINGHarmful Gas — Do not release the gas until all crew members have evacuated the machinery space — Do not re-enter the machinery space until all gas has been removed and the space declared safeAVERTISSEMENTGaz nocif — Ne pas libérer le gaz avant que tous les membres d’équipage aient évacué le local de machines — Ne pas retourner dans le local avant que tout le gaz ait été éliminé et que le local soit déclaré sécuritaire
(2) A placard containing the following warning must be posted near the means of control for a fixed aerosol fire-extinguishing system:WARNINGHarmful Aerosol — Do not release the aerosol until all crew members have evacuated the machinery space — Do not re-enter the machinery space until all aerosol has been removed and the space declared safeAVERTISSEMENTAérosol nocif — Ne pas libérer l’aérosol avant que tous les membres d’équipage aient évacué le local de machines — Ne pas retourner dans le local avant que tout l’aérosol ait été éliminé et que le local soit déclaré sécuritaire
(3) A placard containing the following warning must be posted at the entrance to an occupied machinery space:DANGERSpace protected by fire-extinguishing system — Vacate space immediately when alarm soundsDANGERLocal protégé par un système d’extinction d’incendie — Quitter le local immédiatement lorsque l’alarme retentit
(4) Clear instructions for the safe operation of a fixed fire-extinguishing system must be kept near the means of control for the system.
(5) The procedure to follow in case of a fire in a machinery space must be posted at each fire control station and must include instructions for
(a) stopping the ventilation fans that serve the space;
(b) shutting off the source of power or fuel for any machinery or equipment in the space that could contribute to sustaining a fire or create any other unsafe condition in the case of fire;
(c) closing the openings to the space;
(d) ensuring that nobody is in the space; and
(e) venting the space after the release of the extinguishing agent into the space, using an opening vented to outside the vessel and not to a location in the vicinity of a muster station or to any location where passengers or crew are present.
Read the Vessel Fire Safety Regulations on the Justice Laws Website ↗
Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.