Vessel Fire Safety Regulations, SOR/2017-14

Section 316

Cite as Vessel Fire Safety Regulations, SOR/2017-14, s. 316 · current to July 24, 2025 · regulation last amended November 23, 2022

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The exposed surface of insulating materials fitted on the internal boundaries of machinery spaces must be impervious to oil and oil vapours. (2) All thermal insulation and acoustic insulation, including pipe and ventilation lagging, must be non-combustible. (3) Polyurethane foam or other organic foam insulation must not be used unless it is (a) used to insulate a cargo space or a cold room or similar galley service space, sealed with a fire retardant coating of the intumescent type and covered with a steel-sheet protective facing; or (b) used as a flotation material that is installed in a dedicated and enclosed space and protected from fire risks.
Read the Vessel Fire Safety Regulations on the Justice Laws Website ↗

Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.