Vessel Fire Safety Regulations, SOR/2017-14

Section 121

Cite as Vessel Fire Safety Regulations, SOR/2017-14, s. 121 · current to July 24, 2025 · regulation last amended November 23, 2022

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) In addition to the requirements of regulation 9.4.2.1, the following requirements must be met: (a) the gap between every door leaf and its frame in an “A” class division, as installed on board the vessel, must not exceed the gap measured when the door was tested in accordance with the FTP Code, but, in the case where the door was approved without a sill being part of the frame, the gap under the door, as installed on board the vessel, must not exceed the gap set out in regulation 9.4.2.1 for an “A” class division; (b) a grille or louvre must not be fitted in a door in an “A” class division; and (c) every door in an “A” or “B” class division must be fitted with a thin metal identification plate that (i) has clearly stamped on it the door manufacturer’s name, the “A” or “B” class rating, the type approval certificate number and the number of the drawing to which the door has been manufactured, and (ii) is screwed or riveted to either of the vertical edges of the door panel. (2) For the purposes of regulation 9.4.2.2, if hold-back arrangements fitted with remote-release devices of the fail-safe type are utilized, (a) the arrangements must be capable of being operated at the door and from the wheelhouse; and (b) a fire door open-close indicator panel must be provided in the wheelhouse.
Read the Vessel Fire Safety Regulations on the Justice Laws Website ↗

Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.