Vessel Fire Safety Regulations, SOR/2017-14

Section 112

Cite as Vessel Fire Safety Regulations, SOR/2017-14, s. 112 · current to July 24, 2025 · regulation last amended November 23, 2022

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) In addition to the requirements of regulation 5.2, a vessel must be fitted with means to automatically shut down the ventilation fans for a space when a fixed gas fire-extinguishing system for that space is activated. (2) In addition to the requirements of regulation 5.2.2.3, a vessel must be fitted with a means of control if the vessel is provided with any other equipment than that referred to in that regulation, including hydraulic power systems, that could contribute to sustaining a fire or create any other unsafe condition in the case of fire, in the space in which that other equipment is fitted.
Read the Vessel Fire Safety Regulations on the Justice Laws Website ↗

Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.