Vessel Fire Safety Regulations, SOR/2017-14

Section 111

Cite as Vessel Fire Safety Regulations, SOR/2017-14, s. 111 · current to July 24, 2025 · regulation last amended November 23, 2022

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

The mechanical ventilation system required by regulation 4.5.4.1 must (a) permit the extraction of air from the cargo pump room bilges or from immediately above the transverse floor plates or bottom longitudinals; (b) have an emergency intake that is (i) situated in the ventilation ducts at a height of at least 2 m above the lower platform of the cargo pump room, and (ii) fitted with a fire damper that is capable of being opened and closed from the weather deck or the lower platform of the cargo pump-room; and (c) provide a means of ensuring a free flow of gases through the lower platform of the cargo pump-room to the ventilation duct intakes.
Read the Vessel Fire Safety Regulations on the Justice Laws Website ↗

Made under Canada Shipping Act, 2001, S.C. 2001, c. 26.