The text

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas-fired storage water heater described in column 1.TABLEColumn 1Column 2Column 3ItemEnergy-using ProductTesting StandardInformation1Household gas-fired storage water heaters that are manufactured on or after February 3, 1995 and before January 1, 2018CSA P.3-04(a) input rate, in kW (Btu/h);(b) recovery efficiency;(c) type of fuel used;(d) annual energy consumption, in kJ (Btu);(e) first-hour rating, in L;(f) Vr; and(g) energy factor.2Household gas-fired storage water heaters that are manufactured on or after January 1, 2018 and before May 6, 2029CSA P.3-04, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376CSA P.3-15, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376(a) input rate, in kW (Btu/h);(b) recovery efficiency;(c) type of fuel used;(d) annual energy consumption, in kJ (Btu);(e) first-hour rating, in L;(f) Vr;(g) energy factor, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376; and(h) uniform energy factor and Vs, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376.2.1Household gas-fired storage water heaters that are manufactured on or after May 6, 202910 C.F.R. Appendix E(a) input rate, in kW (Btu/h);(b) recovery efficiency;(c) type of fuel used;(d) annual energy consumption, in kJ (Btu);(e) first-hour rating, in L;(f) Vr;(g) Veff; and(h) uniform energy factor.3Commercial gas-fired storage water heaters that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after July 1, 2023CSA P.3-15(a) uniform energy factor;(b) Vr;(c) Vs;(d) input rate, in kW (Btu/h);(e) type of fuel used; and(f) information that indicates whether the product is a replacement unit.4Commercial gas-fired storage water heaters with a Vr of > 530 L (140 US gallons) that are manufactured on or after July 1, 202310 C.F.R. Appendix A(a) thermal efficiency;(b) Vr;(c) Vs;(d) input rate, in kW (Btu/h);(e) type of fuel used; and(f) information that indicates whether the product is a replacement unit.5Commercial gas-fired storage water heaters, other than those described in items 3 and 4, that are manufactured on or after July 1, 202310 C.F.R. Appendix A(a) thermal efficiency;(b) standby loss, in W;(c) Vr;(d) Vs;(e) input rate, in kW (Btu/h);(f) type of fuel used; and(g) information that indicates whether the product is a replacement unit.
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗

Made under Energy Efficiency Act, S.C. 1992, c. 36.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.