Energy Efficiency Regulations, 2016, SOR/2016-311

Section 376

Energy-efficiency standards — household

Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 376 · current to April 28, 2026 · regulation last amended October 9, 2025

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to household gas-fired storage water heaters described in column 1 that are manufactured during the periods set out in column 4. (2) A household gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to a gas-fired storage water heater as defined in subsection 369(1). (3) The energy efficiency standards set out in column 3 of Table 2 to this section apply to commercial gas-fired storage water heaters described in column 1 that are manufactured on or after July 1, 2023. (4) A commercial gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 2 that are applicable to a gas-fired storage water heater as defined in subsection 369(1).TABLE 1Column 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Household gas-fired storage water heatersCSA P.3-04Energy factor of ≥ 0.67 – 0.0005 VrOn or after February 3, 1995 and before December 31, 20162Household gas-fired storage water heatersCSA P.3-04Energy factor of ≥ 0.675 – 0.00039 VrOn or after December 31, 2016 and before January 1, 20183Household gas-fired storage water heaters that have a first-hour rating of < 68 L (18 US gallons)CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factorMust have at least one of the following:(a) energy factor of ≥ 0.675 – 0.00039 Vr; or(b) uniform energy factor of ≥ 0.3456 –0.00053 VsOn or after January 1, 2018 and before May 6, 20294Household gas-fired storage water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons)CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factorMust have at least one of the following:(a) energy factor of ≥ 0.675 – 0.00039 Vr; or(b) uniform energy factor of ≥ 0.5982 – 0.00050 Vs.On or after January 1, 2018 and before May 6, 20295Household gas-fired storage water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons)CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factorMust have at least one of the following:(a) energy factor of ≥ 0.675 – 0.00039 Vr; or(b) uniform energy factor of ≥ 0.6483 – 0.00045 Vs.On or after January 1, 2018 and before May 6, 20296Household gas-fired storage water heaters that have a first-hour rating of ≥ 284 L (75 US gallons)CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factorMust have at least one of the following:(a) energy factor of ≥ 0.675 – 0.00039 Vr; or(b) uniform energy factor of ≥ 0.692 – 0.00034 Vs.On or after January 1, 2018 and before May 6, 20297Household gas-fired storage water heaters10 C.F.R. Appendix EMust have at least one of the following:(a) uniform energy factor of ≥ 0.3456 − 0.00053 Veff, if draw pattern is very-small-usage;(b) uniform energy factor of ≥ 0.5982 − 0.00050 Veff, if draw pattern is low-usage;(c) uniform energy factor of ≥ 0.6483 − 0.00045 Veff, if draw pattern is medium-usage; or(d) uniform energy factor of ≥ 0.692 − 0.00034 Veff, if draw pattern is high-usage.On or after May 6, 2029TABLE 2Column 1Column 2Column 3ItemEnergy-using ProductTesting StandardEnergy Efficiency Standard1Commercial gas-fired storage water heaters, other than replacement units, that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F)CSA P.3-15Uniform energy factor ≥ 0.8107-0.00021 Vs2Commercial gas-fired storage water heaters that are replacement units, have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F)CSA P.3-15Uniform energy factor ≥ 0.6597-0.00024 Vs3Commercial gas-fired storage water heaters, other than replacement units, that have a Vr of > 530 L (140 US gallons)10 C.F.R. Appendix AThermal efficiency ≥ 90%4Commercial gas-fired storage water heaters that are replacement units and that have a Vr of > 530 L (140 US gallons)10 C.F.R. Appendix AThermal efficiency ≥ 80%5Commercial gas-fired storage water heaters, other than those described in items 1 and 3, that are not replacement units10 C.F.R. Appendix AThermal efficiency ≥ 90%Standby loss ≤ 0.84 (1.25 Q + 16.57√Vs)6Commercial gas-fired storage water heaters, other than those described in items 2 and 4, that are replacement units10 C.F.R. Appendix AThermal efficiency ≥ 80%Standby loss ≤ 1.25 Q + 16.57√Vs
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗

Made under Energy Efficiency Act, S.C. 1992, c. 36.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.