Energy Efficiency Regulations, 2016, SOR/2016-311
Section 260
Information
Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 260 · current to April 28, 2026 · regulation last amended October 9, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas furnace described in column 1.TABLEColumn 1Column 2Column 3ItemEnergy-using ProductTesting StandardInformation1Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured before December 31, 2009CSA 2.3(a) heating capacity, in kW (Btu/h); and(b) annual fuel utilization efficiency.2Gas furnaces, other than those that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after December 31, 2009 and before July 3, 2019CSA P.2(a) maximum heat input and output nominal capacities, in kW (Btu/h);(b) annual fuel utilization efficiency;(c) information that indicates whether product has an integrated cooling component;(d) if product has an integrated cooling component, information that indicates whether the product is outdoor or through-the-wall;(e) standby power, in W;(f) power burner’s PE and VPE; and(g) type of fuel used.2.1Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after July 3, 2019CSA P.2, for information set out in paragraphs (a) to (e)10 C.F.R. Appendix AA, for information set out in paragraphs (f) and (g)(a) maximum heat input and output nominal capacities, in kW (Btu/h);(b) annual fuel utilization efficiency;(c) information that indicates whether product has an integrated cooling component;(d) if product has an integrated cooling component, information that indicates whether the product is outdoor or through-the-wall;(e) type of fuel used;(f) FER, expressed in W/472 L/s (W/1,000 ft³/min);(g) product’s maximum airflow (Qmax), expressed in L/s (ft³/min); and(h) if applicable, information that indicates whether product is gas furnace for relocatable buildings or is replacement non-condensing gas furnace.2.2Gas furnaces that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current, that have an integrated cooling component and that are manufactured on or after December 31, 2009 and before January 1, 2024CSA P.2 for information set out in paragraphs (a) to (c)(a) maximum heat input and output nominal capacities, in kW (Btu/h);(b) annual fuel utilization efficiency;(c) type of fuel used; and(d) if applicable, information that indicates whether product is gas furnace for relocatable buildings or is replacement non-condensing gas furnace.2.3Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that have an integrated cooling component and that are manufactured on or after January 1, 2024CSA P.2 for information set out in paragraphs (a) to (c)(a) maximum heat input and output nominal capacities, in kW (Btu/h);(b) annual fuel utilization efficiency;(c) type of fuel used; and(d) type of blower fan motor, namely brushless permanent magnet, permanent split-capacitor or other.3Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and that use three-phase electric currentCSA 2.3(a) heating capacity, in kW (Btu/h); and(b) annual fuel utilization efficiency or thermal efficiency.4Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h)CSA 2.3(a) heating capacity, in kW (Btu/h); and(b) thermal efficiency.5Gas furnaces for relocatable buildings manufactured on or after January 1, 2024CSA P.2 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix AA for information set out in paragraphs (d) and (e)(a) maximum heat input and output nominal capacities, in kW (Btu/h);(b) annual fuel utilization efficiency;(c) type of fuel used;(d) FER, expressed in W/472 L/s (W/1,000 ft3/min); and(e) product’s maximum airflow (Qmax), expressed in L/s (ft3/min).6Replacement non-condensing gas furnaces manufactured on or after January 1, 2024CSA P.2 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix AA for information set out in paragraphs (d) and (e)(a) maximum heat input and output nominal capacities, in kW (Btu/h);(b) annual fuel utilization efficiency;(c) type of fuel used;(d) FER, expressed in W/472 L/s (W/1,000 ft3/min); and(e) product’s maximum airflow (Qmax), expressed in L/s (ft3/min).
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗
Made under Energy Efficiency Act, S.C. 1992, c. 36.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.