Energy Efficiency Regulations, 2016, SOR/2016-311
Section 259
Energy efficiency standards
Cite as Energy Efficiency Regulations, 2016, SOR/2016-311, s. 259 · current to April 28, 2026 · regulation last amended October 9, 2025
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The energy efficiency standards set out in column 3 of the table to this section apply to gas furnaces described in column 1 that are manufactured during the periods set out in column 4.
(2) A gas furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas furnace as defined in section 257.TABLEColumn 1Column 2Column 3Column 4ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture1Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use single-phase electric currentCSA 2.3Annual fuel utilization efficiency ≥ 78%On or after February 3, 1995 and before December 31, 20092Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling componentCSA P.2Annual fuel utilization efficiency ≥ 90%On or after December 31, 2009 and before July 3, 20192.1Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling componentCSA P.2, for annual fuel utilization efficiency10 C.F.R. Appendix AA, for FERAnnual fuel utilization efficiency ≥ 95%FER ≤ FER for product class “Non-Weatherized, Condensing Gas Furnace Fan (NWG-C)”, set out in 10 C.F.R. §430.32(y)On or after July 3, 20193Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling componentCSA P.2Annual fuel utilization efficiency ≥ 78%On or after December 31, 2009 and before July 3, 20193.1Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling componentCSA P.2, for annual fuel utilization efficiency10 C.F.R. Appendix AA, for FERAnnual fuel utilization efficiency ≥ 78%FER ≤ FER for product class “Weatherized Non-Condensing Gas Furnace Fan (WG-NC)”, set out in 10 C.F.R. §430.32(y)On or after July 3, 20194Gas furnaces that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling componentCSA P.2Annual fuel utilization efficiency ≥ 78%On or after December 31, 2009 and before December 31, 20125Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling componentCSA P.2Annual fuel utilization efficiency ≥ 90%On or after December 31, 2012 and before January 1, 20245.1Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, have an input rate of ≤ 65.92 kW (225,000 Btu/h) and have an integrated cooling componentCSA P.2Annual fuel utilization efficiency ≥ 90%On or after January 1, 20246Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use three-phase electric currentCSA 2.3Annual fuel utilization efficiency ≥ 78%orThermal efficiency ≥ 80%On or after February 3, 19957Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h)CSA 2.3Thermal efficiency ≥ 80%On or after February 3, 19958Gas furnaces for relocatable buildingsCSA P.2 for annual fuel utilization efficiency10 C.F.R. Appendix AA, for fan energy ratingAnnual fuel utilization efficiency ≥ 80%FER ≤ FER for product class “Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC)”, set out in 10 C.F.R. §430.32(y)On or after July 3, 20199Replacement non-condensing gas furnacesCSA P.2 for annual fuel utilization efficiency10 C.F.R. Appendix AA, for fan energy ratingAnnual fuel utilization efficiency ≥ 80%FER ≤ FER for product class “Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC)”, set out in 10 C.F.R. §430.32(y)On or after July 3, 2019
Read the Energy Efficiency Regulations, 2016 on the Justice Laws Website ↗
Made under Energy Efficiency Act, S.C. 1992, c. 36.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.