Multi-Sector Air Pollutants Regulations, SOR/2016-151

Section 88

Emissions check — sampling procedure

Cite as Multi-Sector Air Pollutants Regulations, SOR/2016-151, s. 88 · current to January 19, 2026 · regulation last amended January 1, 2026

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

(1) The emissions check must be conducted — on an engine’s exhaust gas introduced into the analyzer at a constant flow rate — during a 15-minute sampling period by (a) taking a reading of each of its electrochemical cells’ responses to, as applicable, O2, CO, NO and NO2 in the exhaust gas at least once each minute during that period and at least 15 seconds after a previous reading; or (b) recording the average, over each minute of that period, of each of those cells’ responses to, as applicable, O2, CO, NO and NO2 in the exhaust gas. (2) If the emissions check is conducted with an analyzer that does not display negative concentrations, the NO cell temperature must be recorded at least once each minute during the 15-minute sampling period. (3) The sampling period begins after the end of the period that begins with the introduction of the engine’s exhaust gas into the analyzer for the emissions check and that has a duration determined by the formula2Ts + {π/4 × [(dE2 × LE)/QE − (dC2 × LC)/QC]}whereTsis the stabilization period, expressed in seconds, referred to in subsection 83(5) for the most recent sequence of calibration error checks conducted on the analyzer;dEis the greatest diameter, expressed in m, of any tube that is used in the measurement system through which the engine’s exhaust gas flows from the sampling port or traverse point to the analyzer during the emissions check;LEis the total length, expressed in m, of those tubes that are used during the emissions check;QEis the flow rate, expressed in m3/s, of the engine’s exhaust gas measured by the analyzer during the emissions check;dCis the smallest diameter, expressed in m, of any tube that is used in the measurement system through which the span gas flows from the point where it is introduced into the measurement system to the analyzer during the most recent sequence of calibration error checks conducted on the analyzer;LCis the total length, expressed in m, of those tubes that are used during the most recent sequence of calibration error checks conducted on the analyzer; andQCis the flow rate, expressed in m3/s, of the span gas for NO measured by the analyzer during the most recent sequence of calibration error checks conducted on the analyzer.
Read the Multi-Sector Air Pollutants Regulations on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.