The text

(1) The location of the sampling port, and its traverse points, in the exhaust pipe for each test run must be determined in accordance with (a) EPA Method 1 or EPA Method 1A, as applicable; (b) ASTM D6522-11; or (c) EC Method A. (2) If a pre-existing engine does not have a sampling port that meets the requirements of any of those methods, each test run must (a) be conducted at a single traverse point that is located at the centre of the exhaust pipe at a distance from the engine of at least twice the diameter of that pipe; and (b) have the NOx emission intensity of the engine expressed in ppmvd15%. (3) If an after-treatment control device is used, either (a) the location of the sampling port described by subsection (1) must also be downstream of the device; or (b) for the purpose of paragraph (2)(a), the location of the single traverse point must be downstream of the device — rather than the engine — at a distance from the device of at least twice the diameter of the exhaust pipe.