Multi-Sector Air Pollutants Regulations, SOR/2016-151
Section 19
Determination of Ldfg
Cite as Multi-Sector Air Pollutants Regulations, SOR/2016-151, s. 19 · current to January 19, 2026 · regulation last amended January 1, 2026
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
Ldfg referred to in section 18 must be determined for an hour in the given day by the formula1.005 × (Tg – Ti)/HHVm × Mg × 100whereTgis the average temperature, expressed in °C, of the flue gas, as measured in the stack, during that hour;Tiis the average temperature , expressed in °C, of the air introduced into the combustion chamber during that hour;HHVmis the higher heating value of the fuel combusted during that hour, expressed on a mass basis in kJ/kg, being(a) for commercial grade natural gas,(i) the higher heating value, determined in accordance with any of the required HHV methods set out in section 22 that apply, or(ii) 51 800 kJ/kg, and(b) in any other case, the weighted average of the higher heating value of each fuel combusted during that hour, expressed on a mass basis in kJ/kg, determined in accordance with any of the required HHV methods set out in section 22 that apply; andMgis the average ratio of the mass of the flue gas to the mass of the fuel combusted, expressed in kg/kg, during that hour, determined by the formula0.962 × [1 + %O2/(20.9 – %O2)] × Mswhere%O2is the percentage of oxygen, determined by volume on a dry basis, in the flue gas, determined in accordance with EPA Method 3A or ASTM D6522-11,Msis the ratio of the stoichiometric mass of the flue gas to the mass of the fuel combusted, expressed in kg/kg, being(a) for commercial grade natural gas,(i) the ratio determined in accordance with paragraph (b), or(ii) 15.3 kg/kg, and(b) in any other case, the ratio determined by the formula:12.492C + 26.296H + N + 5.305S – 3.313Owhere the concentration of each of the following constituents of the fuel combusted is determined in accordance with subsections 23(1) and (2) andCis the concentration of carbon in the fuel combusted, expressed in kg of carbon per kg of that fuel,His the concentration of hydrogen in the fuel combusted, expressed in kg of hydrogen per kg of that fuel,Nis the concentration of nitrogen in the fuel combusted, expressed in kg of nitrogen per kg of that fuel,Sis the concentration of sulphur in the fuel combusted, expressed in kg of sulphur per kg of that fuel, andOis the concentration of oxygen in the fuel combusted, expressed in kg of oxygen per kg of that fuel.
Read the Multi-Sector Air Pollutants Regulations on the Justice Laws Website ↗
Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.