Multi-Sector Air Pollutants Regulations, SOR/2016-151

Section 15

Input energy from gaseous fossil fuel

Cite as Multi-Sector Air Pollutants Regulations, SOR/2016-151, s. 15 · current to January 19, 2026 · regulation last amended January 1, 2026

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

The percentage of the input energy in a boiler’s or heater’s combustion chamber resulting from the introduction of gaseous fossil fuel, for a given hour while the boiler or heater is in a steady state, must be determined by the formula(Ecng + Egff)/(Ecng + Egff + Eo + Es) × 100whereEcngis the input energy resulting from the introduction of commercial grade natural gas for the given hour, determined by the formulaQcng × HHVcngwhereQcngis the quantity of the commercial grade natural gas combusted during the given hour, as measured by a flow meter on the input, expressed in standard m3, andHHVcngis the higher heating value of the commercial grade natural gas combusted during the given hour, expressed in GJ/standard m3, being(a) the higher heating value determined in accordance with any of the required HHV methods set out in section 22 that apply, or(b) 0.03793;Egffis the input energy resulting from the introduction of gaseous fossil fuel, other than commercial grade natural gas, for the given hour, determined by the formulaQgff × HHVgffwhereQgffis the quantity of the gaseous fossil fuel, other than commercial grade natural gas, combusted during the given hour, as measured by a flow meter on the input, expressed in standard m3, andHHVgffis the higher heating value of the gaseous fossil fuel, other than commercial grade natural gas, combusted during the given hour, expressed in GJ/standard m3, determined in accordance with any of the required HHV methods set out in section 22 that apply;Eois the input energy resulting from the introduction of a fuel other than gaseous fossil fuel during the given hour, determined by the formulaΣi(Qi × HHVi)whereQiis the quantity of the ith fuel other than gaseous fossil fuel combusted during the given hour as measured by a flow meter on the input, expressed in a given unit,HHViis the higher heating value of the ith fuel other than gaseous fossil fuel combusted during the given hour, expressed in GJ/the given unit, being(a) the higher heating value determined in accordance with any of the required HHV methods set out in section 22 that apply, or(b) the default higher heating value set out in column 2 of the applicable table to Schedule 3 for the type of fuel set out in column 1 of that table, andiis the ith fuel other than gaseous fossil fuel combusted, where i goes from 1 to n and where n is the number of those fuels combusted; andEsis the input energy, expressed in GJ, that originates from a source other than the combustion of fuel in the boiler’s or heater’s combustion chamber during the given hour, determined in accordance with generally accepted engineering principles.
Read the Multi-Sector Air Pollutants Regulations on the Justice Laws Website ↗

Made under Canadian Environmental Protection Act, 1999, S.C. 1999, c. 33.

Bills in Parliament that would change this section 0

No bill we hold would amend or repeal this section.