Wastewater Systems Effluent Regulations, SOR/2012-139
Section 14
Un-ionized ammonia
Cite as Wastewater Systems Effluent Regulations, SOR/2012-139, s. 14 · current to June 14, 2026 · regulation last amended June 4, 2026
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The concentration of un-ionized ammonia in the effluent must be determined in accordance with the following formula:total ammonia × 11 +109.56 – pHwheretotal ammoniais the concentration of total ammonia determined in accordance with subsection (2), expressed in mg/L as nitrogen (N); andpHis the pH of the effluent adjusted to 15°C ± 1°C and determined in accordance with subsection (3).
(2) The concentration of total ammonia in the effluent must be determined by using an aliquot of the same sample of effluent from which the pH of the effluent was determined and testing it in accordance with a total ammonia test.
(3) The pH of the effluent must be determined by using an aliquot of the same sample of effluent from which the concentration of total ammonia of the effluent was determined and testing it in accordance with a pH test.
Read the Wastewater Systems Effluent Regulations on the Justice Laws Website ↗
Made under Fisheries Act, R.S.C. 1985, c. F-14.