Every person that controls the release of hexavalent chromium compounds from a tank by using a tank cover must ensure that the cover is closed while chromium electroplating, chromium anodizing or reverse etching is taking place and that the cover has the following characteristics: (a) it completely encloses the open surface area of the tank; (b) it has a seal that joins the cover to the tank; (c) it has a membrane that is inset in the cover, that has a minimum surface area of 0.28 m2/kA of current and that has pore openings not larger than 1 µm; and (d) it has an evacuation device that is attached to the outside of the cover and that has a HEPA filter with pore openings not larger than 0.1 µm.