The text
(1) Approach and exit ramps to and from a permanently installed vehicle scale shall
(a) be straight for a distance of at least 3 m adjacent to the weighbridge;
(b) be as wide as, and in the same plane as, the weighbridge;
(c) be constructed, for a distance of at least 3 m adjacent to the weighbridge, of concrete or similar durable material to ensure that they remain smooth, level and in the same plane as the weighbridge; and
(d) beyond the 3 m distance set out in paragraphs (a) and (c), be constructed so as to permit
(i) easy access by the vehicle being weighed,
(ii) ready access for testing purposes, and
(iii) any water to drain away from the scale.
(2) Where approach and exit ramps to and from a permanently installed vehicle scale include grating, the grating shall be of sufficient strength to withstand all loads that are intended to be supported by the scale.
Read the Specifications Relating to Non-automatic Weighing Devices (1998) on the Justice Laws Website ↗
Made under Weights and Measures Act, R.S.C. 1985, c. W-6.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.