Specifications Relating to Non-automatic Weighing Devices (1998), SI/98-81
Section 62
Cite as Specifications Relating to Non-automatic Weighing Devices (1998), SI/98-81, s. 62 · current to July 24, 2025 · regulation last amended June 17, 2019
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) A weighing device that is used in an application described in column 1 of the table to this section shall be from the accuracy class set out in column 2 for that device, or from a higher accuracy class, and shall be used to weigh a load that is not less than the amount obtained by multiplying the verification scale interval by the corresponding multiplying factor set out in column 3, and the device’s smallest verification scale interval shall not exceed that set out in column 4.
(2) A weighing device described in subsection 2(2) that is used or intended to be used in an application described in column 1 of the table to this section and that is not marked with an accuracy class designation shall, for the purpose of applying these Specifications, be considered to be of the corresponding accuracy class set out in column 2 of that table.
(3) In this section, primary elevator, terminal elevator and transfer elevator have the meaning given to them in section 2 of the Canada Grain Act.TABLEItemColumn 1Column 2Column 3Column 4Minimum net load expressed as a number of verification scale intervalsApplicationAccuracy classVerification scale intervalMultiplying factorMaximum verification scale interval permitted1Weighing precious metals and commodities of comparable value(a) at the retail levelOval outline with the text II inside– – –– – –10 mg(b) at the wholesale or industrial levelOval outline with the text II insidee ≤ 10 mg– – –– – –e ≥ 20 mg2 000– – –2Weighing diamonds or other gemstonesOval outline with the text II inside– – –– – –1 mg or 0.005 carat3Weighing to determine postal, transportation or shipping charges, except when determined by means of a weighing device with a maximum capacity of 4 000 kg (10 000 pounds) or moreOval outline with the text III insidee ≤ 50 g (2 ounces)10– – –e > 50 g (2 ounces)20– – –4Weighing gravel, land fill and other raw material for road constructionOval outline with the text IIII insidee50– – –5Weighing waste material other than scrap metalOval outline with the text IIII insidee10– – –6Weighing scrap metal (ferrous)Oval outline with the text IIIHD insidee20– – –7Weighing scrap metal (non-ferrous)Oval outline with the text IIIHD insidee100– – –8Weighing grain at a primary, transfer or terminal elevator, or alcohol, by means of a weighing device with a maximum capacity of 4 000 kg (10 000 pounds) ormoreOval outline with the text IIIHD insidee200– – –9Weighing bulk commodities, other than the commodities referred to in items 1 to 8, by means of a weighing device with a maximum capacity of 4 000 kg (10 000 pounds) or moreOval outline with the text IIIHD insidee100– – –10Any other applicationOval outline with the text III inside0.1 g ≤ e ≤ 2 g20– – –e = 5 g20– – –5 g < e < 50 g50– – –e ≥50 g100– – –Note: See table to section 3 for equivalent Canadian units.
Read the Specifications Relating to Non-automatic Weighing Devices (1998) on the Justice Laws Website ↗
Made under Weights and Measures Act, R.S.C. 1985, c. W-6.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.