Specifications Relating to Non-automatic Weighing Devices (1998), SI/98-81
Section 44
Cite as Specifications Relating to Non-automatic Weighing Devices (1998), SI/98-81, s. 44 · current to July 24, 2025 · regulation last amended June 17, 2019
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) The zero-tracking mechanism of a weighing device shall not be operator-controlled.
(2) The maximum load corrected at any one time by the zero-tracking mechanism of a weighing device shall not exceed 0.6 times the verification scale interval.
Read the Specifications Relating to Non-automatic Weighing Devices (1998) on the Justice Laws Website ↗
Made under Weights and Measures Act, R.S.C. 1985, c. W-6.