Specifications Relating to Non-automatic Weighing Devices (1998), SI/98-81

Section 43

Cite as Specifications Relating to Non-automatic Weighing Devices (1998), SI/98-81, s. 43 · current to July 24, 2025 · regulation last amended June 17, 2019

Statute Watch

Get an alert when a bill in Parliament would change this section, and every time it moves.

The text

The overall range of the initial zero-setting mechanism shall not exceed 20 per cent of the maximum capacity of the weighing device unless the device can perform within the applicable limits of error for any amount of initial load compensated by such mechanism.
Read the Specifications Relating to Non-automatic Weighing Devices (1998) on the Justice Laws Website ↗

Made under Weights and Measures Act, R.S.C. 1985, c. W-6.