Weights and Measures Regulations, C.R.C., c. 1605
Section 268
Cite as Weights and Measures Regulations, C.R.C., c. 1605, s. 268 · current to July 24, 2025 · regulation last amended September 20, 2024
Statute Watch
Get an alert when a bill in Parliament would change this section, and every time it moves.
The text
(1) Subject to subsection (7), the limits of error set out in the tables to subsections (2) to (6) apply in respect of all meters that are designed to measure liquefied gases at ambient temperatures.
(2) The limits of error set out in the table to this subsection apply in respect of meters of a size from 25 mm to 50 mm or one inch to two inches, when tested using the liquefied gases the meters are intended to measure and using a narrow neck metal standard of the vapour displacement type.TABLEColumn IColumn IIColumn IIIItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of ErrorLitresGallons1225 or more50 or more0.5% of known test quantity1% of known test quantity
(3) The limits of error set out in the table to this subsection apply in respect of meters of a size 25 mm or larger or one inch or larger, except meters referred to in paragraph (4)(a), when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard.TABLEColumn IColumn IIColumn IIIItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of ErrorLitresGallons1225 or more50 or more0.25% of known test quantity0.5% of known test quantity
(4) The limits of error set out in the table to this subsection apply in respect of
(a) meters used to dispense liquid propane to motor vehicles, when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard; and
(b) meters of a size smaller than 25 mm or one inch, when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard.TABLEColumn IColumn IIColumn IIIItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of ErrorLitresGallons1 5160 mL or 2 fluid ounces120 mL or 4 fluid ounces210285 mL or 3 fluid ounces170 mL or 6 fluid ounces320 or more4 or more0.5% of known test quantity1% of known test quantity
(5) The limits of error set out in the table to this subsection apply in respect of
(a) meters used to dispense liquid propane to motor vehicles, when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard; and
(b) meters of a size smaller than 25 mm or one inch, when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard.TABLEColumn IColumn IIColumn IIIItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of ErrorLitresGallons1from 25 to 45from 5 to 101.5%2%2more than 45more than 100.8%1%
(6) The limits of error set out in the table to this subsection apply in respect of meters of a size 25 mm or larger or one inch or larger, except meters referred to in paragraph (5)(a), when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard.TABLEColumn IColumn IIColumn IIIItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of ErrorLitresGallons1from 100 to 200from 20 to 450.75%1%2more than 200more than 450.75%0.75%
(7) The acceptance limits of error set out in Column II of the tables to subsections (2) to (6) apply only in respect of tests made under controlled conditions, and for tests made under other conditions the limits of error set out in Column III of those tables apply.
Read the Weights and Measures Regulations on the Justice Laws Website ↗
Made under Weights and Measures Act, R.S.C. 1985, c. W-6.
Bills in Parliament that would change this section 0
No bill we hold would amend or repeal this section.