Pennsylvania 2025_0 Regular Session Status: In Committee Sponsors 10 R

HB 2516 — An Act amending the act of July 31, 1968 (P.L.805, No.247), known as the Pennsylvania Municipalities Planning Code, in general provisions, further providing for definitions; in comprehensive plan, providing for comprehensive plan element for commercial data centers; and, in zoning, providing for zoning, commercial data centers and agricultural land protections and for zoning, commercial data centers, approval procedure and minimum standards.

Last action — Referred to LOCAL GOVERNMENT, May 13, 2026

Write to your legislator about it: a free email template →

No card. One bill, free forever — alerts when it moves.

  1. ✓
    Introduced
  2. 2
    In Committee
  3. 3
    Passed House
  4. 4
    Passed Senate
  5. 5
    To Executive
  6. 6
    Enacted

This bill is in committee in the House. Introduced May 13, 2026. It must pass committee before a floor vote.

Next likely step: a committee vote, then a floor vote in the House.

In plain language

This bill establishes regulations for commercial data centers in Pennsylvania municipalities.

The bill amends the Pennsylvania Municipalities Planning Code to include specific provisions for commercial data centers. It outlines standards for zoning, land use, and protections for agricultural areas.

What this means for you
  • Users: Municipalities will need to align their planning and zoning with the new data center standards.

Summary

Data Center Bill Package

Bill Text

How this bill changes current law

8 changes Share ↗

AI-generated reading aid from the bill's amendatory text — verify against the official bill.

The bill introduces regulations and standards for commercial data centers within the Pennsylvania Municipalities Planning Code, particularly focusing on their impact on agricultural land and community planning.

  • Section 107

    "Commercial data center," a facility, campus of facilities or array of interconnected facilities located within this Commonwealth that: (1) is predominantly used to house and operate equipment that receives, stores, aggregates, manages, processes, transforms, retrieves, researches or transmits data; and (2) has a peak demand of 25 megawatts or greater.

    Defines what constitutes a commercial data center for planning purposes.

  • Section 301.6

    If a municipality's comprehensive plan includes commercial data centers, the plan shall identify: (1) areas generally appropriate for the use of a data center, including where public infrastructure and utility capacity is available or planned; and (2) agricultural resources to be avoided, including prime agricultural land, agricultural security areas and land subject to agricultural conservation easements.

    Requires comprehensive plans to consider the location of commercial data centers carefully, particularly regarding agricultural land.

  • Section 603.2

    If a zoning ordinance authorizes commercial data centers in any zoning district, the zoning ordinance shall include standards that address: (1) setbacks and buffering from residential uses; (2) noise, lighting and landscaping mitigation; (3) documentation evidencing adequate water supply, sewage disposal and storm water management consistent with applicable law; (4) emergency response planning; and (5) decommissioning, including standards for the removal of structures and equipment and restoration of the site after the commercial data center ceases operation.

    Mandates specific zoning standards for commercial data centers to mitigate their impact on surrounding areas.

  • Section 603.2(b)

    A zoning ordinance may not permit and no governing body or zoning hearing board may approve, authorize or grant relief to allow a commercial data center on a tract, lot or parcel that is: (1) within an agricultural security area; or (2) subject to an agricultural conservation easement.

    Prohibits commercial data centers from being located on agricultural areas to protect agricultural resources.

  • Section 603.3

    A commercial data center shall not be permitted in a municipality unless the zoning ordinance expressly authorizes the use in a zoning district.

    Ensures that commercial data centers can only be established in areas where they are specifically permitted by local ordinances.

  • Section 603.3(b)

    Unless a municipality adopts a more restrictive requirement, the zoning ordinance shall require: (1) a setback of not less than 2,500 feet between any principal building of a commercial data center and the nearest boundary line of any parcel containing a dwelling; (2) a setback of not less than 300 feet from any public road right-of-way; and (3) maximum height limits for principal buildings and accessory structures.

    Imposes minimum setback and height regulations to minimize disturbances from commercial data centers.

  • Section 603.3(c)

    In addition to the notice required under section 908 for an application for conditional use or special exception approval of a commercial data center, the municipality shall ensure the following: (1) The applicant submits to the municipality, and the municipality makes available for public inspection, a plain-language project summary; (2) Written notice of the hearing is mailed to owners of real property located within one mile of the boundaries of the tract; (3) A conspicuous notice is posted on the affected tract not less than 30 days prior to the first hearing.

    Enhances public transparency and engagement regarding the approval process for commercial data centers.

  • Section 603.3(e)

    Following the public hearing, a municipality may prohibit commercial data centers in all zoning districts if the governing body finds that the use would be inconsistent with the municipality's statement of community development objectives.

    Gives municipalities the authority to entirely prohibit commercial data centers if deemed inconsistent with community goals.

Action History

  1. Referred to LOCAL GOVERNMENT, May 13, 2026

Sponsors

Sponsorship breakdown

Export CSV (upgrade) →

1 sponsors · 9 co-sponsors · 243 not signed on

Sponsors (1)

Co-sponsors (9)

Not signed on (243)

243 members have not signed on to this bill.

Show all 243 →

"Not signed on" means a member has not sponsored or co-sponsored this bill — it does not imply opposition. Members flagged Voted No have a recorded No vote on this bill.

Whip count is in markup. Polling the chamber and every recorded vote this session. Only the first open is slow. It’s instant for you after this. Calling the roll · Tallying · Engrossing

Committees

Cross-referencing the record. Reading this bill against every other bill in the corpus by meaning, not keywords. Only the first open is slow. It’s instant for you after this. Matching · Ranking · Engrossing

Frequently asked questions

What does HB 2516 do?
Data Center Bill Package
Who sponsors HB 2516?
HB 2516 is sponsored by Mark M. Gillen (Republican), Jamie Walsh (Republican), Charity Grimm Krupa (Republican), Steven C. Mentzer (Republican), Jill N. Cooper (Republican), Brenda M. Pugh (Republican), Scott Barger (Republican), Jacob D. Banta (Republican), Wendy Fink (Republican), and Kerry A. Benninghoff (Republican).
What is the current status of HB 2516?
This bill is in committee in the House. Introduced May 13, 2026. It must pass committee before a floor vote.
Where can I track HB 2516?
Track HB 2516 free on One Click Politics — get push/email alerts when it moves.

Make your voice heard on HB 2516

Find the representatives who decide this bill and tell them where you stand — for yourself, or mobilize your whole list in one click with One Click Politics advocacy software.

Stay ahead of HB 2516

Last checked for changes about 1 month ago · updated continuously

One Click Politics tracks every bill in Congress and all 50 states.

Track this bill →