2017-07476: Airworthiness Directives; General Electric Company Turbofan Engines
Get alerted when the next rule lands
New rules open for comment on their own schedule. Pick how you want to hear about them — we email you when one appears.
Publishing to members? Embed a live rule tracker on your own site — the proposed rules in your area and the comment deadlines closing on them, updating themselves. Free, one line of HTML.
Create a free account & build one →Summary
We are superseding Airworthiness Directive (AD) 2016-13-05 for all General Electric Company (GE) GE90-76B, GE90-77B, GE90-85B, GE90- 90B, and GE90-94B turbofan engines. AD 2016-13-05 required eddy current inspection (ECI) of the high-pressure compressor (HPC) stage 8-10 spool at each shop visit for all affected engines and ECI or ultrasonic inspection (USI) for certain affected engines. This new AD requires initial and repetitive on-wing USIs of the HPC stage 8-10 spool for certain engines prior to shop visit and ECI of all affected engines at each shop visit. This AD was prompted by analysis that the risk of the failure of an HPC stage 8-10 spool was excessive without repetitive USI prior to shop visit. We are issuing this AD to correct the unsafe condition on these products.
The agency’s own summary, as published.
What this changes
Amends 1 part of the Code of Federal Regulations — the standing rules this notice rewrites.
Rulemaking docket
We haven’t pulled this rulemaking’s full docket yet. View docket FAA-2015-7491 on Regulations.gov →
Don't miss the comment window
One Click Politics alerts you on every deadline, hearing, and rule change.