Minister of Municipal Affairs and Housing Regulation

B.C. Reg. 1/2018: Amendments to the British Columbia Building Code Regulation

Made under the Building Act

How does this rule affect your organization? One Click reads it against your profile and tells you, on Canada Federal Legislative Tracking. See plans →

Get alerted when the next rule lands

New rules land on their own schedule. Pick how you want to hear about them — we email you when one appears.

Publishing to members? Embed a live rule tracker on your own site — the proposed rules in your area and the comment deadlines closing on them, updating themselves. Free, one line of HTML.

The rule, in full

3,294 words as published, January 16, 2018. View the original →

B.C. Reg. 1/2018, deposited January 9, 2018, under the BUILDING ACT [section 3]. Ministerial Order M13/2018, dated January 8, 2018. I, Selina Robinson, Minister of Municipal Affairs and Housing, order that (a) effective January 31, 2018, the British Columbia Building Code Regulation, B.C. Reg. 264/2012, is amended as set out in the attached Schedule, and (b) an applicant for a building permit as defined in section 3 of the British Columbia Building Code Regulation, B.C. Reg. 264/2012, is exempt from the amendments set out in the attached Schedule in respect of a building permit application submitted before January 31, 2018, if (i) the building permit applied for is issued and work commences and continues to completion without interruption, other than work stoppages considered reasonable in the building industry, and (ii) all work is carried out in conformity with the British Columbia Building Code Regulation, B.C. Reg. 264/2012, except the amendments set out in the attached Schedule. — S. ROBINSON, Minister of Municipal Affairs and Housing.

Schedule

1 Book I (General) of the British Columbia Building Code established by the British Columbia Building Code Regulation, B.C. Reg. 264/2012, is amended as set out in this Schedule. Division 1 – Changes to Division B 2 Table 1.3.1.2. of Division B is amended by repealing the following item: CAN/CGSB | CAN/CGSB 149.10-M86 | Determination of the Airtightness of Building Envelopes by the Fan Depressurization Method | 9.36.5.10.(11) 9.36.6.5.(1) and substituting the following: CGSB | CAN/CGSB 149.10-M86 | Determination of the Airtightness of Building Envelopes by the Fan Depressurization Method | 9.36.5.10.(11) 9.36.6.5.(1) 3 Clause 9.8.8.1.(6)(a) is amended by striking out “the window serves a dwelling unit that is not located above another suite,” and substituting “Reserved.”. 4 Clause 9.32.3.4.(6)(a) is amended by adding “except for a secondary suite,” at the beginning of Subclause (iv). 5 Sentence 9.36.5.10.(10) is amended by striking out “Where airtightness is measured in accordance with Clause 9.36.5.10.(9) (c)” and substituting “Where airtightness is measured in accordance with Clause 9.36.5.10.(9)(c)”. 6 Article 9.36.6.2. is amended (a) by adding “(See Appendix A.)” below the heading, (b) in Sentence (1) by adding “by the building” after “energy used over a year” and by striking out “area of conditioned space” and substituting “floor area of conditioned space”, (c) in Sentence (3) by striking out “area of conditioned space” and substituting “floor area of conditioned space” and in Clause (d) by striking out “air barrier system” and substituting “air barrier system”, and (d) in Sentence (4) by striking out “and expressed in watts per square metre of area (W/m2) of conditioned space” and substituting “, normalized per square metre of floor area of conditioned spaceand expressed in W/m2”. 7 Article 9.36.6.3. is amended (a) by repealing the following Tables: Table 9.36.6.3.A. Requirements for Buildings Located Where the Degree-Days Below 18°C Value is less than 3000(1) Forming Part of Sentence 9.36.6.3.(1) Step | Airtightness (Air Changes per Hour at 50 Pa Pressure Differential) | Performance Requirement of Building Equipment and Systems | Performance Requirement of Building Envelope 1 | N/A | EnerGuide Rating % lower than EnerGuide Reference House: not less than 0% lower energy consumption or conform to Subsection 9.36.5. 2 | ≤ 3.0 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 10% lower energy consumption or mechanical energy use intensity ≤ 60 kWh/m2∙year | thermal energy demand intensity ≤ 45 kWh/(m2∙year) or peak thermal load ≤ 35 W/m2 3 | ≤ 2.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 20% lower energy consumption or mechanical energy use intensity ≤ 45 kWh/m2∙year | thermal energy demand intensity ≤ 40 kWh/(m2∙year) or peak thermal load ≤ 30 W/m2 4 | ≤ 1.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 40% lower energy consumption or mechanical energy use intensity ≤ 35 kWh/m2∙year | thermal energy demand intensity ≤ 25 kWh/(m2∙year) or peak thermal load ≤ 25 W/m2 5 | ≤ 1.0 | mechanical energy use intensity ≤ 25 kWh/m2∙year | thermal energy demand intensity ≤ 1 5kWh/(m2∙year) or peak thermal load ≤ 10 W/m2 Notes to Table 9.36.6.3.A.: (1) See Sentence 1.1.3.1.(1) of this Division and Table C-2 in Appendix C. Table 9.36.6.3.B. Requirements for Buildings Located Where the Degree-Days Below 18°C Value is 3000 to 3999(1) Forming Part of Sentence 9.36.6.3.(1) Step | Airtightness (Air Changes per Hour at 50 Pa Pressure Differential) | Performance Requirement of Building Equipment and Systems | Performance Requirement of Building Envelope 1 | N/A | EnerGuide Rating % lower than EnerGuide Reference House: not less than 0% lower energy consumption or conform to Subsection 9.36.5. 2 | ≤ 3.0 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 10% lower energy consumption or mechanical energy use intensity ≤ 90 kWh/(m2∙year) | thermal energy demand intensity ≤ 60 kWh/(m2∙year) or peak thermal load ≤ 55 W/m2 3 | ≤ 2.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 20% lower energy consumption or mechanical energy use intensity ≤ 75 kWh/(m2∙year) | thermal energy demand intensity ≤ 50 kWh/(m2∙year) or peak thermal load ≤ 45 W/m2 4 | ≤ 1.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 40% lower energy consumption or mechanical energy use intensity ≤ 45 kWh/(m2∙year) | thermal energy demand intensity ≤ 40 kWh/(m2∙year) or peak thermal load ≤ 40 W/m2 5 | ≤ 1.0 | mechanical energy use intensity ≤ 25 kWh/(m2∙year) | thermal energy demand intensity ≤ 15 kWh/(m2∙year) or peak thermal load ≤ 10 W/m2 Notes to Table 9.36.6.3.B.: (1) See Sentence 1.1.3.1.(1) of this Division and Table C-2 in Appendix C. Table 9.36.6.3.C. Requirements for Buildings Located Where the Degree-Days Below 18°C Value is greater than 3999(1) Forming Part of Sentence 9.36.6.3.(1) Step | Airtightness (Air Changes per Hour at 50 Pa Pressure Differential) | Performance Requirement of Building Equipment and Systems | Performance Requirement of Building Envelope 1 | N/A | EnerGuide Rating % lower than EnerGuide Reference House: not less than 0% lower energy consumption or conform to Subsection 9.36.5. 2 | ≤ 3.0 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 10% lower energy consumption or mechanical energy use intensity ≤ 100 kWh/(m2∙year) | thermal energy demand intensity ≤ 70 kWh/(m2∙year) or peak thermal load ≤ 55 W/m2 3 | ≤ 2.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 20% lower energy consumption or mechanical energy use intensity ≤ 85 kWh/(m2∙year) | thermal energy demand intensity ≤ 60 kWh/(m2∙year) or peak thermal load ≤ 50 W/m2 4 | ≤ 1.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 40% lower energy consumption or mechanical energy use intensity ≤ 55 kWh/(m2∙year) | thermal energy demand intensity ≤ 50 kWh/(m2∙year) or peak thermal load ≤ 45 W/m2 5 | ≤ 1.0 | mechanical energy use intensity ≤ 25 kWh/(m2∙year) | thermal energy demand intensity ≤ 15 kWh/(m2∙year) or peak thermal load ≤ 10 W/m2 Notes to Table 9.36.6.3.C.: (1) See Sentence 1.1.3.1.(1) of this Division and Table C-2 in Appendix C. and substituting the following: Table 9.36.6.3.A Requirements for Buildings Located Where the Degree-Days Below 18°C Value is less than 3000(1) Forming Part of Sentence 9.36.6.3.(1) Step | Airtightness (Air Changes per Hour at 50 Pa Pressure Differential) | Performance Requirement of Building Equipment and Systems | Performance Requirement of Building Envelope 1 | N/A | EnerGuide Rating % lower than EnerGuide Reference House: not less than 0% lower energy consumption or conform to Subsection 9.36.5. 2 | ≤ 3.0 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 10% lower energy consumption or mechanical energy use intensity ≤ 60 kWh/(m2∙year) | thermal energy demand intensity ≤ 45 kWh/(m2∙year) or peak thermal load ≤ 35 W/m2 3 | ≤ 2.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 20% lower energy consumption or mechanical energy use intensity ≤ 45 kWh/(m2∙year) | thermal energy demand intensity ≤ 40 kWh/(m2∙year) or peak thermal load ≤ 30 W/m2 4 | ≤ 1.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 40% lower energy consumption or mechanical energy use intensity ≤ 35 kWh/(m2∙year) | thermal energy demand intensity ≤ 25 kWh/(m2∙year) or peak thermal load ≤ 25 W/m2 5 | ≤ 1.0 | mechanical energy use intensity ≤ 25 kWh/(m2∙year) | thermal energy demand intensity ≤ 15 kWh/(m2∙year) or peak thermal load ≤ 10 W/m2 Notes to Table 9.36.6.3.A: (1) See Sentence 1.1.3.1.(1) of this Division and Table C-2 in Appendix C. Table 9.36.6.3.B Requirements for Buildings Located Where the Degree-Days Below 18°C Value is 3000 to 3999(1) Forming Part of Sentence 9.36.6.3.(1) Step | Airtightness (Air Changes per Hour at 50 Pa Pressure Differential) | Performance Requirement of Building Equipment and Systems | Performance Requirement of Building Envelope 1 | N/A | EnerGuide Rating % lower than EnerGuide Reference House: not less than 0% lower energy consumption or conform to Subsection 9.36.5. 2 | ≤ 3.0 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 10% lower energy consumption or mechanical energy use intensity ≤ 90 kWh/(m2∙year) | thermal energy demand intensity ≤ 60 kWh/(m2∙year) or peak thermal load ≤ 55 W/m2 3 | ≤ 2.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 20% lower energy consumption or mechanical energy use intensity ≤ 75 kWh/(m2∙year) | thermal energy demand intensity ≤ 50 kWh/(m2∙year) or peak thermal load ≤ 45 W/m2 4 | ≤ 1.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 40% lower energy consumption or mechanical energy use intensity ≤ 45 kWh/(m2∙year) | thermal energy demand intensity ≤ 40 kWh/(m2∙year) or peak thermal load ≤ 40 W/m2 5 | ≤ 1.0 | mechanical energy use intensity ≤ 25 kWh/(m2∙year) | thermal energy demand intensity ≤ 15 kWh/(m2∙year) or peak thermal load ≤ 10 W/m2 Notes to Table 9.36.6.3.B: (1) See Sentence 1.1.3.1.(1) of this Division and Table C-2 in Appendix C. Table 9.36.6.3.C Requirements for Buildings Located Where the Degree-Days Below 18°C Value is greater than 3999(1) Forming Part of Sentence 9.36.6.3.(1) Step | Airtightness (Air Changes per Hour at 50 Pa Pressure Differential) | Performance Requirement of Building Equipment and Systems | Performance Requirement of Building Envelope 1 | N/A | EnerGuide Rating % lower than EnerGuide Reference House: not less than 0% lower energy consumption or conform to Subsection 9.36.5. 2 | ≤ 3.0 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 10% lower energy consumption or mechanical energy use intensity ≤ 100 kWh/(m2∙year) | thermal energy demand intensity ≤ 70 kWh/(m2∙year) or peak thermal load ≤ 55 W/m2 3 | ≤ 2.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 20% lower energy consumption or mechanical energy use intensity ≤ 85 kWh/(m2∙year) | thermal energy demand intensity ≤ 60 kWh/(m2∙year) or peak thermal load ≤ 50 W/m2 4 | ≤ 1.5 | EnerGuide Rating % lower than EnerGuide Reference House: not less than 40% lower energy consumption or mechanical energy use intensity ≤ 55 kWh/(m2∙year) | thermal energy demand intensity ≤ 50 kWh/(m2∙year) or peak thermal load ≤ 45 W/m2 5 | ≤ 1.0 | mechanical energy use intensity ≤ 25 kWh/(m2∙year) | thermal energy demand intensity ≤ 15 kWh/(m2∙year) or peak thermal load ≤ 10 W/m2 Notes to Table 9.36.6.3.C: (1) See Sentence 1.1.3.1.(1) of this Division and Table C-2 in Appendix C. , and (b) in Sentence (3) by striking out “Tables 9.36.6.3.A. to C.” and substituting “Tables 9.36.6.6.A to C” and by striking out “if the energy model” and substituting “provided the energy model”. 8 Clause 9.36.6.4.(2)(c) is amended by adding “(See Appendix A.)” at the end of the Clause. 9 Article 10.2.2.1. is amended in Sentence (2) by striking out “the remaining major occupancies” and substituting “the major occupancies that do not conform to Subsection 10.2.3.”. 10 Article 10.2.3.2. is amended (a) by adding “(See A-9.36.6.2. in Appendix A.)” below the heading, (b) in Sentence (1) by striking out “the energy, estimated by an energy model” and substituting “the energy used over a year by the building, estimated by using an energy model”, by striking out “used over a year,” and by striking out “from” and substituting “for”, (c) in Sentence (2) by adding “floor” before “area of conditioned space”, (d) in Clause 10.2.3.2.(2)(d) by striking out “air barrier system” and substituting “air barrier system”, and (e) in Sentence (3) by striking out “10.2.3.3.A.” and substituting “10.2.3.3.A”. 11 Article 10.2.3.3. is amended (a) in Sentence (1) by striking out “Except as permitted by Sentence (3), buildings” and substituting “Buildings”, by striking out “designated” and substituting “designed”, and by striking out “10.2.3.3.A.” and substituting “10.2.3.3.A”, and (b) by repealing the following Tables: Table 10.2.3.3.A. Energy Performance Requirements for Residential Occupancies Forming Part of Sentences 10.2.3.3.(1) and (2) Step | Equipment and Systems – Maximum Total Energy Use Intensity (kWh/m2·year) | Building Envelope – Maximum Thermal Energy Demand Intensity (kWh/m2·year) 1 | Conform to Part 8 of the NECB 2 | 130 | 45 3 | 120 | 30 4 | 100 | 15 Table 10.2.3.3.B. Energy Performance Requirements for Business and Personal Services or Mercantile Occupancies Forming Part of Sentences 10.2.3.3.(1) and (2) Step | Equipment and Systems – Maximum Total Energy Use Intensity (kWh/m2·year) | Building Envelope – Maximum Thermal Energy Demand Intensity (kWh/m2·year) 1 | Conform to Part 8 of the NECB 2 | 170 | 30 3 | 120 | 20 and substituting the following: Table 10.2.3.3.A Energy Performance Requirements for Residential Occupancies Forming Part of Sentences 10.2.3.3.(1) and (2) Step | Equipment and Systems – Maximum Total Energy Use Intensity, kWh/(m2·year) | Building Envelope – Maximum Thermal Energy Demand Intensity, kWh/(m2·year) 1 | Conform to Part 8 of the NECB 2 | 130 | 45 3 | 120 | 30 4 | 100 | 15 Table 10.2.3.3.B Energy Performance Requirements for Business and Personal Services or Mercantile Occupancies Forming Part of Sentences 10.2.3.3.(1) and (2) Step | Equipment and Systems – Maximum Total Energy Use Intensity, kWh/(m2·year) | Building Envelope – Maximum Thermal Energy Demand Intensity, kWh/(m2·year) 1 | Conform to Part 8 of the NECB 2 | 170 | 30 3 | 120 | 20 12 Article 10.2.3.4. is amended in Sentence (3) by adding “from total gross above-ground wall and roof areas” before “until the air”. Division 2 – Changes to Appendix A of Division B 13 Appendix A-9.36.1.3. of Division B is amended (a) in the Appendix Note by striking out “to which Section 9.36. and the NECB apply.” and substituting “to which the various compliance paths within Section 9.36. apply.”, and (b) by repealing the following Table: Table A-9.36.1.3. Energy Efficiency Compliance Options for Part 9 Buildings Building Types and Sizes | Energy Efficiency Compliance Options 9.36.2. to 9.36.4. (Prescriptive) | 9.36.5. (Performance) | NECB • houses with or without a secondary suite • buildings containing only dwelling units with common spaces ≤ 20% of building’s total floor area(1) | ✔ | ✔ | ✔ • buildings containing Group D, E or F3 occupancies whose combined total floor area ≤ 300 m2 (excluding parking garages that serve residential occupancies) • buildings with a mix of Group C and Group D, E or F3 occupancies where the non-residential portion’s combined total floor area ≤ 300 m2 (excluding parking garages that serve residential occupancies) | ✔ | X | ✔ • buildings containing Group D, E or F3 occupancies whose combined total floor area > 300 m2 • buildings containing F2 occupancies of any size | X | X | ✔ Notes to Table A-9.36.1.3.: (1) The walls that enclose a common space are excluded from the calculation of floor area of that common space. and substituting the following: Table A-9.36.1.3. Energy Efficiency Compliance Options for Part 9 Buildings Building Types and Sizes | Energy Efficiency Compliance Options 9.36.2. to 9.36.4. (Prescriptive) | 9.36.5. (Performance) | 9.36.6. (Energy Step Code) | NECB • houses with or without a secondary suite • buildings containing only dwelling units with common spaces ≤ 20% of building’s total floor area(1) | ✔ | ✔ | ✔ | ✔ • buildings containing Group D, E or F3 occupancies whose combined total floor area ≤ 300 m2 (excluding parking garages that serve residential occupancies) • buildings with a mix of Group C and Group D, E or F3 occupancies where the non-residential portion’s combined total floor area ≤ 300 m2 (excluding parking garages that serve residential occupancies) | ✔ | X | X | ✔ • buildings containing Group D, E or F3 occupancies whose combined total floor area > 300 m2 • buildings containing F2 occupancies of any size | X | X | X | ✔ Notes to Table A-9.36.1.3.: (1) The walls that enclose a common space are excluded from the calculation of floor area of that common space. 14 The following Appendix Note is added: A-9.36.6.2. Floor Area in the Energy Step Code The words floor area, as used in Sentences 9.36.6.2.(1), 9.36.6.2.(3), 9.36.6.2.(4), 10.2.3.2.(1), and 10.2.3.2.(2), are not italicized, to differentiate them from the defined term floor area in Article 1.4.1.2. of Division A. Different modelling approaches identify the applicable floor area in various ways (e.g. modelled floor area, heated floor area, treated floor area, etc.) and the use of the words floor area in Sentences 9.36.6.2.(1), 9.36.6.2.(3), 9.36.6.2.(4), 10.2.3.2.(1), and 10.2.3.2.(2) is intended to accommodate the various modelling approaches. 15 Appendix Note A-9.36.6.3.(2) is amended by striking out “must also conform” and substituting “may also conform”. 16 Appendix Note A-10.2.1.1.(3) is repealed. 17 Appendix Note A-10.2.3.3.(2) is amended by striking out “Article 10.3.1.4.” and substituting “Article 10.2.3.4.”. 18 Appendix Note A-10.2.3.4.(1)(a) and (2) is amended by striking out “Table 10.2.3.3.A. and Table 10.2.3.3.B.” and substituting “Table 10.2.3.3.A and Table 10.2.3.3.B”. 19 Appendix Note A-10.2.3.4.(3) is amended (a) by repealing the Note heading and substituting the following: A-10.2.3.4.(3) Air Leakage Rate (b) by adding “Air Leakage Rate in Energy Model Calculations” below the Note heading, and (c) by deleting “A-10.2.3.4.(3)” before the headings “Air Leakage Rate in Energy Model Calculations for Step 1” and “Air Leakage Rate”. Division 3 – Changes to Attribution Table of Division B 20 Attribution Table 10.4.1.1. in the Attribution Tables of Division B is amended by repealing the following item: 10.2.1.1. Design (1) | [F85-OE1.1] [F86-OE1.1] (2) | [F85-OE1.1] (3) | [F85-OE1.1] (4) | [F85-OE1.1] (5) | [F85-OE1.1] Division 4 – Changes to Division C 21 Article 2.2.8.1. of Division C is amended by adding the following Sentence: 4) The mechanical energy use intensity in Clause (3)(a), the thermal energy demand intensity in Clause (3)(b), the peak thermal load in Clause (3)(c), and the EnerGuide Rating % lower than EnerGuide Reference House in Clause 3(d) shall account for the airtightness referenced in Clauses (3)(e) or (f), as applicable. 22 Clause 2.2.8.3.(2)(e) is amended by striking out “a statement that the calculation was performed in compliance with Subsection 9.36.5. of Division B.” and substituting “a statement that the calculation was performed in compliance with i) Subsection 9.36.5. of Division B ii) Sentence 9.36.6.3.(3) of Division B, or iii) Sentence 9.36.6.4.(2) of Division B.” 23 Article 2.2.9.2. is amended (a) in Sentence (1) by striking out “plans or specifications” and substituting “drawings or specifications”, (b) in Clause (e) by striking out “Steps 2 to 5” and substituting “Steps 2 to 4”, and (c) in Sentence (2) by striking out “Clause (1)(d).” and substituting “Clauses (1)(d) or (e), as applicable.”. 24 Schedule B is repealed and the attached Schedule B is substituted. 25 Schedule C-A is repealed and the attached Schedule C-A is substituted.