FIREFIGHTERS — PROTECTIVE EQUIPMENT, O. Reg. 714/94
Section 6
Cite as FIREFIGHTERS — PROTECTIVE EQUIPMENT, O. Reg. 714/94, s. 6 · current to November 11, 2026 · consolidated from July 1, 2022 · read from e-Laws on November 16, 2026
The text
(1) In this section,
“chassis mounted aerial device” means any device, whether extensible, articulating or both, that is mounted on a vehicle’s chassis and designed to position persons, handle materials or discharge water, but does not include portable ladders. O. Reg. 714/94, s. 6 (1).
(2) Subject to subsection (3), a chassis mounted aerial device shall be visually inspected by a competent person at the times recommended by the manufacturer but in any event at least once every calendar year. O. Reg. 714/94, s. 6 (2).
(3) Every chassis mounted aerial device shall be visually inspected by a competent person,
(a) before being used for the first time;
(b) after every major repair;
(c) after being used if it may have been subjected to unusual operating conditions of stress or load; and
(d) when there is reason to believe that the maximum loads or stresses recommended in the manufacturer’s operating specifications have been exceeded. O. Reg. 714/94, s. 6 (3).
(4) Every chassis mounted aerial device shall be tested using a method of inspection that does not physically alter or damage material,
(a) when a visual inspection indicates a potential hazard; and
(b) not later than December 15, 1999 for the first such testing and subsequently not later than five years from the date of the last non-destructive testing. O. Reg. 714/94, s. 6 (4).
(5) The visual inspection and non-destructive tests under this section shall be performed in accordance with NFPA 1914, Standard for Testing Fire Department Aerial Devices, 1991 Edition, excluding section 1-7. O. Reg. 714/94, s. 6 (5).
(6) If a visual inspection or any test reveals a hazard to the integrity of the chassis mounted aerial device, the employer shall ensure that,
(a) the chassis mounted aerial device is taken out of service;
(b) the repairs, if any, are undertaken by a competent person; and
(c) if the repairs involve welding, the welds are inspected and approved by an inspector who is a Level III Welding Inspector under CSA Standard W178.2-1990 Certification of Welding Inspectors, and who is employed by an organization certified under CSA Standard W178.1-1990 Certification of Welding Inspection Organizations. O. Reg. 714/94, s. 6 (6).
(7) Service records for a chassis mounted aerial device shall be maintained for as long as the device is in service and shall include a record of,
(a) visual inspections;
(b) non-destructive and other tests;
(c) the problems identified;
(d) the repairs made; and
(e) the name and signature of the competent persons who undertook the activities mentioned in clauses (a) to (d). O. Reg. 714/94, s. 6 (7).
Read the FIREFIGHTERS — PROTECTIVE EQUIPMENT on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.