DIVING OPERATIONS, O. Reg. 629/94

Section 27

Cite as DIVING OPERATIONS, O. Reg. 629/94, s. 27 · current to November 11, 2026 · consolidated from July 1, 2025 · read from e-Laws on November 16, 2026

The text

The diving supervisor for a diving operation shall ensure that, (a) each diver wears an adequate bailout system that meets the requirements of Clause 4.7.3 of CSA Standard Z275.2-11, “Occupational Safety Code for Diving Operations”; (b) every submersible compression chamber is equipped with an emergency reserve breathing gas supply that is adequate for all of the chamber’s occupants for at least 24 hours; (c) every submersible compression chamber is equipped with an emergency reserve breathing gas supply that can provide all lock-out divers with at least 30 minutes of breathing gas at a rate of 40 litres per minute; and (d) every atmospheric diving system is equipped with an emergency reserve breathing gas supply that is adequate for all of the system’s occupants for at least 48 hours. O. Reg. 32/14, s. 25.
Read the DIVING OPERATIONS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.