HEALTH CARE AND RESIDENTIAL FACILITIES, O. Reg. 67/93
Section 79
Cite as HEALTH CARE AND RESIDENTIAL FACILITIES, O. Reg. 67/93, s. 79 · current to November 11, 2026 · consolidated from June 9, 2025 · read from e-Laws on November 16, 2026
The text
(1) Lifting equipment shall be thoroughly examined by a competent person to determine its capability of handling the maximum load as rated,
(a) before being used for the first time; and
(b) thereafter as often as necessary but not less frequently than recommended by the manufacturer and, in any case, at least once a year.
(2) A permanent record shall be kept of each examination conducted under subsection (1) for as long as the equipment remains on the premises and for one year after the equipment is removed and the record shall be signed by the person who conducted it.
(3) Lifting equipment shall be clearly marked with sufficient information to enable its operator to determine the maximum rated load that the equipment is capable of lifting under any operating condition.
(4) If lifting equipment is equipped with limit switches, the switches shall,
(a) automatically cut off the power;
(b) automatically apply the brake when a load reaches its permissible limit; and
(c) be used as an operating control only when designed for such use.
(5) If a limit switch is used as an operating control on lifting equipment, a second limit switch shall be located behind the first switch.
(6) The lifting equipment’s controls shall be attended when its load is in the raised position.
(7) Lifting equipment shall be attended when the forks, bucket, blades or similar part is in the raised position unless,
(a) the equipment is a hydraulic or pneumatic hoist that supports the load from below and is fixed in one location; or
(b) the forks, bucket, blades or similar part is solidly supported. O. Reg. 67/93, s. 79.
Read the HEALTH CARE AND RESIDENTIAL FACILITIES on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.