HEALTH CARE AND RESIDENTIAL FACILITIES, O. Reg. 67/93

Section 37

Cite as HEALTH CARE AND RESIDENTIAL FACILITIES, O. Reg. 67/93, s. 37 · current to November 11, 2026 · consolidated from June 9, 2025 · read from e-Laws on November 16, 2026

The text

A guardrail shall be designed and constructed to meet the requirements for guardrails as set out in Parts 3 and 4 of the Ontario Building Code or it shall, (a) have a horizontal top rail located not less than ninety-one and not more than 107 centimetres above the surface to be guarded; (b) have an intermediate rail located midway between the top rail and the surface to be guarded; (c) if tools or other objects may fall on a worker, have a toe-board that extends from the surface to be guarded to a height of not less than 125 millimetres; (d) be constructed to meet the structural requirements for guardrails as set out in Part 4 of the Ontario Building Code; and (e) be free of splinters and other hazardous protrusions. O. Reg. 67/93, s. 37.
Read the HEALTH CARE AND RESIDENTIAL FACILITIES on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.