CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 82

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 82 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) This section applies if a portable ladder is used as a means of access and egress between, (a) levels of a building or structure; (b) the ground or grade level to a building or structure; or (c) different work surface levels. O. Reg. 345/15, s. 13. (2) The ladder, (a) shall extend at the upper level at least 900 millimetres above the landing surface; (b) shall, subject to subsection (3), have a clear space of at least 150 millimetres behind every rung; (c) shall be located so that an adequate landing surface that is clear of obstructions is available at the top and bottom of the ladder for access and egress; and (d) shall be secured at the top and bottom to prevent movement of the ladder. O. Reg. 345/15, s. 13. (3) Clause (2) (b) does not apply to a ladder lying on an excavation wall that is sloped, as required by section 234. O. Reg. 345/15, s. 13.
Read the CONSTRUCTION PROJECTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.