CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 74

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 74 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) A ramp shall have, (a) a slope not exceeding a gradient of 1 in 3; and (b) if its slope exceeds a gradient of 1 in 8, cross cleats made from nineteen millimetres by thirty-eight millimetres boards that are securely nailed to the ramp and spaced at regular intervals not exceeding 500 millimetres. O. Reg. 213/91, s. 74 (1). (2) Subsection (1) does not apply to a ramp installed in the stairwell of a building not exceeding two storeys in height if the ramp, (a) has a slope not exceeding a gradient of 1 in 1; and (b) has cross cleats made from thirty-eight millimetres by thirty-eight millimetres boards that are securely nailed to the ramp and spaced at regular intervals not exceeding 300 millimetres. O. Reg. 213/91, s. 74 (2).
Read the CONSTRUCTION PROJECTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.