CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 365

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 365 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) An air lock, including the bulkheads and doors, shall be designed by an engineer in accordance with good engineering practice to withstand the pressures to be used in the work chamber and in the air lock. O. Reg. 213/91, s. 365 (1); O. Reg. 375/22, s. 5. (2) An air lock shall be constructed in accordance with the engineer’s design drawings for it. O. Reg. 213/91, s. 365 (2); O. Reg. 375/22, s. 4. (3) An air lock used for people, (a) shall measure at least two metres laterally and vertically; (b) shall be large enough to accommodate the maximum number of people expected to be in the work chamber without them being in cramped positions; (c) other than an ancillary air lock that complies with section 367, shall contain a functional and accurate electric time piece, thermometer and pressure gauge. O. Reg. 213/91, s. 365 (3). (4) The constructor shall send to a Director before construction of an air lock begins a copy of the design drawings for the air lock. O. Reg. 213/91, s. 365 (4); O. Reg. 145/00, s. 40; O. Reg. 85/04, s. 24. (5) The constructor shall keep at a project a copy of the design drawings for an air lock while the air lock is at the project. O. Reg. 213/91, s. 365 (5).
Read the CONSTRUCTION PROJECTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.