CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 314

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 314 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) The air inlet to an air compressor shall be located in such a position that fumes or noxious contaminants are not drawn in with the air to be compressed. O. Reg. 213/91, s. 314 (1). (2) A valve connected to a vessel used for storing compressed air, (a) shall be connected at the lowest point of the vessel to permit the discharge of the compressed air; and (b) shall be opened at least once each shift for the purpose of ejecting oil, water and other matter from the vessel. O. Reg. 213/91, s. 314 (2).
Read the CONSTRUCTION PROJECTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.