CONSTRUCTION PROJECTS, O. Reg. 213/91
Section 288
Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 288 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026
The text
(1) This section applies with respect to a hoistway that is more than six metres deep in which hoisting is carried out by mechanical power. O. Reg. 213/91, s. 288 (1).
(2) Every landing on a hoistway shall have a gate located 200 millimetres or less from the hoistway that,
(a) extends the full width of the hoistway from 50 millimetres or less from the floor level to a height of at least 1.8 metres;
(b) is constructed without any gaps that would permit the entry of a ball no more than thirty-eight millimetres in diameter; and
(c) is equipped with a light readily visible to the hoist operator indicating when the gate is closed. O. Reg. 213/91, s. 288 (2); O. Reg. 142/17, s. 30.
(3) Subsection (2) does not apply to a landing at the bottom of a hoistway if the landing has one or more red lights that,
(a) are located where a person approaching the hoistway from a tunnel or from the lower end of a stair or ladder can see at least one of them; and
(b) are controlled by a switch readily accessible to a shaft attendant. O. Reg. 213/91, s. 288 (3).
(4) A gate required by subsection (2) shall be kept closed unless a conveyance is stopped at the landing. O. Reg. 213/91, s. 288 (4).
(5) The red lights referred to in subsection (3) shall be continuously flashed off and on during a hoisting operation. O. Reg. 213/91, s. 288 (5).
Read the CONSTRUCTION PROJECTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.