CONSTRUCTION PROJECTS, O. Reg. 213/91
Section 276
Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 276 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026
The text
(1) An area of a tunnel or shaft that is not adequately lit by natural light shall be electrically illuminated. O. Reg. 213/91, s. 276 (1).
(2) Flashlights shall be readily available at the top and bottom of every shaft and near the work face of a tunnel. O. Reg. 213/91, s. 276 (2).
(3) If electric lighting is used in a tunnel or shaft, an emergency lighting system shall be installed in the tunnel or shaft. O. Reg. 213/91, s. 276 (3).
(4) An emergency lighting system,
(a) shall be connected to the electrical supply so that in the event of the failure of the electrical supply, the system will automatically turn on;
(b) shall be provided with a testing switch, if the system is battery-powered; and
(c) shall be tested at least as frequently as is recommended by its manufacturer to ensure that the system will function in an emergency. O. Reg. 213/91, s. 276 (4).
Read the CONSTRUCTION PROJECTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.