CONSTRUCTION PROJECTS, O. Reg. 213/91
Section 242
Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 242 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026
The text
(1) A metal trench-jack or trench-brace may be used in place of a timber strut,
(a) if the allowable working load of the trench-jack or trench-brace is equal to or greater than that of the timber strut; and
(b) if the size of the replaced timber strut is shown on the trench-jack or trench-brace. O. Reg. 213/91, s. 242 (1).
(2) The allowable working load of a metal trench-jack or trench-brace shall be determined by an engineer in accordance with good engineering practice and shall be legibly cast or stamped on the trench-jack or trench-brace. O. Reg. 213/91, s. 242 (2); O. Reg. 375/22, s. 5.
(3) No metal trench-jack or trench-brace shall be extended beyond the length used to establish its maximum allowable working load. O. Reg. 213/91, s. 242 (3).
(4) Every metal trench-jack or trench-brace, when it is used,
(a) shall be placed against the wales in such a way that the load from the wales is applied axially to the trench-jack or trench-brace; and
(b) shall be adequately supported so that it does not move out of position. O. Reg. 213/91, s. 242 (4).
Read the CONSTRUCTION PROJECTS on e-Laws ↗