CONSTRUCTION PROJECTS, O. Reg. 213/91

Section 211

Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 211 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026

The text

(1) Only a competent worker shall operate a hot tar or bitumen roadtanker or kettle. O. Reg. 213/91, s. 211 (1). (2) If a hot tar or bitumen roadtanker or kettle is fitted with a propane-fuelled heater, (a) the storage cylinder for propane shall not be placed closer than three metres to a source of fire or ignition; (b) the lines connecting the storage cylinder for propane to the heating device shall be located so that they do not come into contact with the hot tar or bitumen in the case of a spill or a failure of a component of the system; and (c) a fire extinguisher with an Underwriters’ Laboratories of Canada rating of at least 4A40BC shall be provided with the roadtanker or kettle. O. Reg. 213/91, s. 211 (2). (3) A propane burner used on a bitumen roadtanker or kettle, (a) shall have a thermal rating no greater than that recommended by the manufacturer of the roadtanker or kettle; and (b) shall consist of components that are adequate for their intended use. O. Reg. 213/91, s. 211 (3). (4) Hot tar or bitumen shall be transferred from a roadtanker to a kettle through enclosed piping. O. Reg. 213/91, s. 211 (4).
Read the CONSTRUCTION PROJECTS on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.