CONSTRUCTION PROJECTS, O. Reg. 213/91
Section 171
Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 171 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026
The text
(1) A cable used by a crane or other hoisting device shall be adequately attached,
(a) by binding and fastening the cable around an oval thimble in a way that is strong enough to prevent the cable thimble from separating;
(b) by fastening the cable within a tapered socket by means of virgin zinc or epoxy resin; or
(c) by fastening the cable with a wedge-type socket fitted with a wire rope clip at the dead end to prevent the accidental release or loosening of the wedge. O. Reg. 241/23, s. 24.
(2) The dead end cable of a wedge socket assembly on a hoisting line shall extend between 100 millimetres and 300 millimetres out of the socket. O. Reg. 241/23, s. 24.
(3) All wire rope terminations used on a tower crane shall be proof tested after installation onto the wire rope in accordance with the recommendations of the wire rope or termination manufacturer, but in no case to more than 50 per cent of the wire rope’s nominal or minimum rated breaking strength, and permanent records of the proof testing shall be kept for the life of the terminations. O. Reg. 241/23, s. 24.
(4) Despite subsection (3), wire rope terminations installed onto the wire rope used on a tower crane that is in service on the date section 24 of Ontario Regulation 241/23 comes into force shall be proof tested before the wire rope is put into subsequent service. O. Reg. 241/23, s. 24.
Read the CONSTRUCTION PROJECTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.