CONSTRUCTION PROJECTS, O. Reg. 213/91
Section 121
Cite as CONSTRUCTION PROJECTS, O. Reg. 213/91, s. 121 · current to November 11, 2026 · consolidated from April 20, 2026 · read from e-Laws on November 16, 2026
The text
(1) Every explosive load for an explosive actuated fastening tool,
(a) shall be marked or labelled so that a worker can easily identify its strength; and
(b) shall be stored in a locked container unless it is required for immediate use. O. Reg. 213/91, s. 121 (1).
(2) No explosive load for an explosive actuated fastening tool,
(a) shall be stored in a container with explosive loads of other strengths; or
(b) shall be left unattended where it may be available to a worker who is not qualified to operate an explosive actuated fastening tool. O. Reg. 213/91, s. 121 (2).
(3) A misfired explosive load removed from an explosive actuated fastening tool shall be placed in a water-filled container on the project until the misfired explosive load is removed from the project. O. Reg. 213/91, s. 121 (3).
Read the CONSTRUCTION PROJECTS on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.