WELLS, R.R.O. 1990, Reg. 903
Section 15.1
Cite as WELLS, R.R.O. 1990, Reg. 903, s. 15.1 · current to November 11, 2026 · consolidated from January 1, 2020 · read from e-Laws on November 16, 2026
The text
(1) If a new well is constructed by any method, the person constructing the well shall ensure that the well is vented to the outside atmosphere in a manner that will safely disperse all gases. O. Reg. 372/07, s. 16.
(2) Subsection (1) does not apply to,
(a) a test hole; or
(b) a well in which casing is used to transmit water out of the well. O. Reg. 372/07, s. 16.
(3) If a pump is installed in a drilled well, the person constructing the well shall ensure that,
(a) an air vent is installed with a minimum inside diameter of,
(i) 0.3 centimetres, if the inside diameter of the casing is less than 12.7 centimetres, or
(ii) 1.2 centimetres, if the inside diameter of the casing is 12.7 centimetres or more;
(b) the air vent,
(i) is of sufficient length to extend above the covering of the well pit, if a well pit exists, or
(ii) extends above the ground surface a distance sufficient to prevent the entry of flood water from any anticipated flooding in the area but not less than 40 centimetres, if no well pit exists; and
(c) the open end of the air vent is shielded and screened in a manner sufficient to prevent the entry of any materials into the well. O. Reg. 372/07, s. 16.
(4) Subsection (3) does not apply to an uncased test hole or an uncased dewatering well. O. Reg. 372/07, s. 16.
(5) Subsection (3) does not apply to the following wells if there is no potential hazard from natural gas or any other gas:
1. A well with a well pit.
2. A test hole or dewatering well described in subsection 13 (11). O. Reg. 372/07, s. 16.
Read the WELLS on e-Laws ↗
Made under Ontario Water Resources Act, R.S.O. 1990, c. O.40.