X-RAY SAFETY, R.R.O. 1990, Reg. 861

Section 6

Cite as X-RAY SAFETY, R.R.O. 1990, Reg. 861, s. 6 · current to November 11, 2026 · consolidated from July 1, 2021 · read from e-Laws on November 16, 2026

The text

(1) An X-ray source shall not be installed or used in a permanent location and an X-ray source that is designed for portable or mobile use shall not be installed or used regularly in one location unless an application for review, together with plan location drawings, of the installation have been reviewed by and are acceptable to an inspector. (2) Subsection (1) does not apply to an X-ray source that, (a) was in use in a permanent location before the 27th day of April, 1984, if it has remained continuously in that location since that time and so long as it remains in that location; or (b) was installed after the 26th day of April, 1984, if the installation was made in compliance with Ontario Regulation 263/84 and there was compliance with that Regulation until the end of the 29th day of October, 1986. (3) An application mentioned in subsection (1) shall be in a form obtained from the Ministry and shall be accompanied by the plan location drawings mentioned in that subsection, in duplicate. O. Reg. 106/18, s. 4 (1). (4) Plan location drawings mentioned in subsection (1), (a) shall bear the name of the applicant and the address of the location; (b) shall be on a legible scale that is not less than 1:100 and that is suitable for microfilming; (c) shall indicate the direction north; (d) shall show the proposed location of the X-ray source and, where applicable, the range of its motion; (e) shall show the proposed location of the X-ray control panel, if the location of the control panel is different from that of the X-ray source; (f) shall indicate the use of rooms or areas that are adjacent, both horizontally and vertically, to the proposed location; (g) shall indicate the type and thickness of the shielding installed or to be installed on the boundaries of the proposed location; and (h) shall indicate the type and location of the safety devices such as warning lights, interlocks and cut-off switches. (5) An application under this section shall be filed with a Director. O. Reg. 106/18, s. 4 (2). (6) Where an application under this section or a predecessor of this section has been found acceptable by an inspector, the X-ray source to which the application relates shall not be installed except in accordance with the application and the plan location drawings as accepted by the inspector. (7) An X-ray source to which subsection (1) applies or that is described in subsection (2) shall not be used, if after the installation of the X-ray source there is a change in, (a) the installation or use of the X-ray source; (b) the use of rooms or areas adjacent, horizontally or vertically, to the X-ray source; or (c) any shielding of the X-ray source, that may result in an increase in the exposure of a worker to X-rays unless the change has been reviewed by and is acceptable to an inspector. (8) An employer shall request a review of a change described in subsection (7) by giving the request to a Director. O. Reg. 106/18, s. 4 (2).
Read the X-RAY SAFETY on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.