WINDOW CLEANING, R.R.O. 1990, Reg. 859
Section 30
Cite as WINDOW CLEANING, R.R.O. 1990, Reg. 859, s. 30 · current to November 11, 2026 · consolidated from July 1, 2022 · read from e-Laws on November 16, 2026
The text
(1) Every outrigger beam, cornice hook and parapet wall hook that is used to support a primary support line,
(a) shall be capable of supporting at least four times the maximum load to which it may be subjected,
(i) without overturning, and
(ii) without exceeding the allowable unit stress for the materials of which it is constructed;
(b) shall be constructed of steel, aluminum or equivalent material; and
(c) shall be tied back to a fixed support so as to prevent movement of the outrigger beam, cornice hook or parapet wall hook.
(2) Every outrigger beam that is used to support a primary support line,
(a) shall have counterweights that are manufactured for the purpose, marked to indicate their weight and securely attached to the outrigger beam;
(b) shall be accompanied by the supplier’s or manufacturer’s instructions indicating the number of counterweights necessary for each arrangement of the beam that may be employed for window cleaning and the load that the beam can bear for each arrangement; and
(c) if it is positioned on a rolling undercarriage, shall have the undercarriage fixed to prevent the counterweights from moving while a worker is suspended by the primary support line. R.R.O. 1990, Reg. 859, s. 30.
Read the WINDOW CLEANING on e-Laws ↗
Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.