OIL AND GAS — OFFSHORE, R.R.O. 1990, Reg. 855

Section 97

Cite as OIL AND GAS — OFFSHORE, R.R.O. 1990, Reg. 855, s. 97 · current to November 11, 2026 · consolidated from July 1, 2022 · read from e-Laws on November 16, 2026

The text

Electrical equipment shall, (a) comply with, (i) the Institute of Electrical and Electronics Engineers Recommended Practice for Electrical Installations on Shipboard Standard 45-1983, if the equipment was installed before July 1, 2019, or (ii) the Institute of Electrical and Electronics Engineers Recommended Practice for Electrical Installations on Shipboard Standard 45-2002, if the equipment was installed on or after July 1, 2019; (b) be explosion proof, (i) within at least four metres horizontally from the centre line of the well bore, (ii) within at least three metres vertically above the drill floor, (iii) within at least three metres vertically below the drill floor, (iv) within at least three metres vertically and horizontally from a mud ditch, shale shaker, degasser and mud tank, and (v) in any enclosed high fire hazard area; (c) be suitable for its intended use; and (d) be equipped with two manual shut off switches located distant from each other, which will disconnect the circuit from the power plant to the drilling equipment. R.R.O. 1990, Reg. 855, s. 97; O. Reg. 421/10, s. 18; O. Reg. 188/19, s. 3.
Read the OIL AND GAS — OFFSHORE on e-Laws ↗

Made under Occupational Health and Safety Act, R.S.O. 1990, c. O.1.